Medical electrical equipment Part 2: Particular requirements for the basic safety and essential performance of automatically-controlled brachytherapy afterloading equipment

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$21
Need Help?

This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of automatically-controlled BRACHYTHERAPY AFTERLOADING ME EQUIPMENT, hereafter referred to as ME EQUIPMENT.

If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.

HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard.

NOTE See also 4.2 of the general standard.

This standard applies to automatically-controlled BRACHYTHERAPY AFTERLOADING ME EQUIPMENT used for treatment or alleviation of disease.

This standard specifies requirements

a) for automatically-controlled AFTERLOADING ME EQUIPMENT

1) which contains and uses only beta, gamma, or NEUTRON-emitting SEALED RADIOACTIVE SOURCES, or BRACHYTHERAPY X-RAY SOURCES designed and constructed for use with automatically-controlled AFTERLOADING ME EQUIPMENT,

2) which automatically drives the RADIATION SOURCE(S) from a STORAGE CONTAINER or, in the case of BRACHYTHERAPY X-RAY SOURCES, a reference location outside the PATIENT, to a treatment position inside the SOURCE APPLICATOR(S) and returns the RADIATION SOURCE(S) to the STORAGE CONTAINER or the BRACHYTHERAPY X-RAY SOURCE(S) to the reference location,

3) which is designed for connection to a PATIENT, and

4) with which movements of the RADIATION SOURCE(S) are carried out automatically by the ME EQUIPMENT according to a prescribed programme using a powered mechanism whose changes are controlled by the CONTROLLING TIMER(S) and TIMING DEVICES that are either PROGRAMMABLE ELECTRONIC SUB-SYSTEMS (PESS) (computer or microprocessors) or non-programmable systems and

b) for ME EQUIPMENT intended to be

1) for NORMAL USE, operated under the authority of appropriately licensed or QUALIFIED PERSONS by OPERATORS having the required skills for a particular medical application, for particular specified clinical purposes, e.g. remote AFTERLOADING BRACHYTHERAPY;

2) maintained in accordance within the recommendations given in the INSTRUCTIONS FOR USE;

3) subject to regular quality assurance performance and calibration checks by a QUALIFIED PERSON.

This standard does not specify requirements for SEALED RADIOACTIVE SOURCES. Requirements for the design of X-RAY TUBES used with the ME EQUIPMENT are specified in other IEC standards. See for example: IEC 60601-2-28:2010.

The requirements of this standard are based on the assumptions that:

– a TREATMENT PLAN is available that prescribes appropriate values of the TREATMENT PARAMETERS, and

– the SOURCE STRENGTH(S) or the REFERENCE AIR-KERMA RATE of the RADIATION SOURCE(S) used by the ME EQUIPMENT is (are) known. This standard includes requirements intended to ensure that the prescribed values of the TREATMENT PARAMETERS can be achieved by the ME EQUIPMENT, in particular that:

– the selected RADIATION SOURCE(S) is (are) positioned or moved within the SOURCE APPLICATOR in the selected configuration relative to the SOURCE APPLICATOR;

– IRRADIATION is performed by the selected RADIATION SOURCE configuration for the selected duration;

– IRRADIATION is performed by the ME EQUIPMENT without causing unnecessary RISK to the OPERATOR or other persons in the immediate surroundings.


Edition : 16
File Size : 1 file , 550 KB
Number of Pages : 50
Published : 01/01/2016

History

CEI EN 60601-2-17
Published Date: 03/01/2017
Apparecchi elettromedicali Parte 2: Prescrizioni particolari relative alla sicurezza fondamentale e alle prestazioni essenziali degli apparecchi proiettori automatici di sorgenti gamma con comando automatico
$21
CEI EN 60601-2-17
Published Date: 01/01/2016
Medical electrical equipment Part 2: Particular requirements for the basic safety and essential performance of automatically-controlled brachytherapy afterloading equipment
$21
CEI EN 60601-2-17
Published Date: 01/01/2006
Medical electrical equipment - Part 2: Particular requirements for the safety of automaticallycontrolled brachytherapy afterloading equipment
$30.3

Related products

CEI EN 62439-7
Published Date: 10/01/2012
Industrial communication networks - High availability automation networks Part 7: Ring-based Redundancy Protocol (RRP)
$70.8
CEI EN 60317-26
Published Date: 09/01/2000
Specifications for particular types of winding wires - Part 26: Polyamide-imide enamelled round copper wire, class 200
$10.5
CEI EN IEC 62453-2
Published Date: 03/01/2023
Field device tool (FDT) interface specification Part 2: Concepts and detailed description
$92.7

Best-Selling Products

IEC/TS 60034-16-2 Ed. 1.0 b:1991
Published Date: 02/15/1991
Rotating electrical machines - Part 16: Excitation systems for synchronous machines - Chapter 2: Models for power system studies
$33
IEC/TS 60034-16-3 Ed. 1.0 b:1996
Published Date: 02/14/1996
Rotating electrical machines - Part 16: Excitation systems for synchronous machines - Section 3: Dynamic performance
$43.5
IEC/TS 60034-17 Ed. 3.0 b:2002
Published Date: 03/26/2002
Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide
$18.3
IEC/TS 60034-17 Ed. 4.0 b:2006
Published Date: 05/09/2006
Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide
$47.1
IEC/TS 60034-18-32 Ed. 1.0 b:1995
Published Date: 03/29/1995
Rotating electrical machines - Part 18: Functional evaluation of insulation systems - Section 32: Test procedures for form-wound windings - Electrical evaluation of insulation systems used in machines up to and including 50 MVA and 15 kV
$18.3
IEC/TS 60034-18-33 Ed. 1.0 b:1995
Published Date: 03/29/1995
Rotating electrical machines - Part 18: Functional evaluation of insulation systems - Section 33: Test procedures for form-wound windings - Multifactor functional evaluation - Endurance under combined thermal and electrical stresses of insulation systems used in machines up to and including 50 MVA a
$32.1