[ Revised ]

Description:

Medical electrical equipment Part 2: Particular requirements for basic safety and essential performance of infusion pumps and controllers

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$36.9
Need Help?

This Particular Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFUSION PUMPS and VOLUMETRIC INFUSION CONTROLLERS, hereafter referred to as ME EQUIPMENT.

This standard applies to ADMINISTRATION SETS insofar as their characteristics influence the BASIC SAFETY or ESSENTIAL PERFORMANCE of INFUSION PUMPS and VOLUMETRIC INFUSION CONTROLLERS. However this standard does not specify requirements or tests for other aspects of ADMINISTRATION SETS

If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.

HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard.

NOTE See also 4.2 of the general standard.

This particular standard specifies the requirements for ENTERAL NUTRITION PUMPS, INFUSION PUMPS, INFUSION PUMPS FOR AMBULATORY USE, SYRINGE OR CONTAINER PUMPS, VOLUMETRIC INFUSION CONTROLLERS and VOLUMETRIC INFUSION PUMPS, as defined in 201.3.204, 201.3.206, 201.3.207, 201.3.220, 201.3.222 and 201.3.223. These particular standard does not apply to the following:

a) devices specifically intended for diagnostic or similar use (e.g. angiography or other pumps permanently controlled or supervised by the OPERATOR);

b) devices for extracorporeal circulation of blood;

c) implantable devices;

d) ME EQUIPMENT specifically intended for diagnostic use within urodynamics (measurement of pressure-volume relationship of the urinary bladder when filled through a catheter with water);

e) ME EQUIPMENT specifically intended for diagnostic use within male impotence testing (measurement of amount of liquid infused, necessary to maintain a preset pressure level for maintaining penile erection: cavernosometry, cavernosography);

f) devices covered by ISO 28620.


Edition : 16
File Size : 1 file , 830 KB
Number of Pages : 68
Published : 01/01/2016

History

CEI EN 60601-2-24
Published Date: 02/01/2018
Apparecchi elettromedicali Parte 2: Prescrizioni particolari relative alla sicurezza fondamentale e alle prestazioni essenziali di pompe d'infusione e di dispositivi di controllo
$36.9
CEI EN 60601-2-24
Published Date: 01/01/2016
Medical electrical equipment Part 2: Particular requirements for basic safety and essential performance of infusion pumps and controllers
$36.9
CEI EN 60601-2-24
Published Date: 07/01/1999
Medical electrical equipment - Part 2: Particular requirements for the safety of infusion pumps and controllers
$37.5

Related products

CEI EN 61400-12-2
Published Date: 12/01/2013
Wind turbines Part 12-2: Power performance of electricity producing wind turbines based on nacelle anemometry
$78.9
CEI EN IEC 61969-3
Published Date: 04/01/2024
Mechanical structures for electrical and electronic equipment - Outdoor enclosures - Part 3: Environmental requirements, tests and safety aspects
$15.9
CEI EN 61169-59
Published Date: 12/01/2017
Radio-frequency connectors Part 59: Sectional specification for type L32-4 and L32-5 threaded multi-pin radio-frequency connectors
$23.7

Best-Selling Products