Name:
CEI EN 60684-3-247/A1 PDF
Published Date:
12/01/2017
Status:
[ Revised ]
Publisher:
Comitato Elettrotecnico Italiano
Introduction
Amendment 1 to IEC 60684-3-247 changes the requirements for peel strength. Major problems have been experienced with reliability and repeatability of results when selecting cable jackets of material types PE, PVC and EPR. The method requires conditioning at 150 ºC, so careful selection of cable jackets that have a minimum rating exceeding this temperature is essential. Even when cables that exceed this temperature are selected experience has shown reproducible adhesive peel forces are difficult to achieve. While it is appreciated that these cable jackets are used with this type of sleevings as recovery of the sleeving is normally achieved by either flame or hot air devices. This means of recovery could be inserted into the method, but extensive testing has shown reproducibly of adhesive peel forces still to be major problem. Due to these issues of lack of reliability and repeatability these substrates have been removed. Lead has also been removed due to health and safety reasons. Additional text has been included to aid clarification of the method that deviates from Clause 54 of IEC 60684-2:2011.
| Edition : | 12 |
| File Size : | 1 file , 1.6 MB |
| Number of Pages : | 10 |
| Published : | 12/01/2017 |