CEI EN 61010-2-020 PDF

CEI EN 61010-2-020 PDF

Name:
CEI EN 61010-2-020 PDF

Published Date:
10/01/2017

Status:
[ Revised ]

Description:

Safety requirements for electrical equipment for measurement, control, and laboratory use Part 2-020: Particular requirements for laboratory centrifuges

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$23.7
Need Help?

Equipment included in scope

This part of IEC 61010 specifies general safety requirements for the following types of electrical equipment and their accessories, wherever they are intended to be used.

a) Electrical test and measurement equipment

This is equipment which by electromagnetic means tests, measures, indicates or records one or more electrical or physical quantities, also non-measuring equipment such as signal generators, measurement standards, power supplies for laboratory use, transducers, transmitters, etc.

NOTE 1 This includes bench-top power supplies intended to aid a testing or measuring operation on another piece of equipment. Power supplies intended to power equipment are within the scope of IEC 61558 (see 1.1.2 h)).

This standard also applies to test equipment integrated into manufacturing processes and intended for testing manufactured devices.

NOTE 2 Manufacturing test equipment is likely to be installed adjacent to and interconnected with industrial machinery in this application.

b) Electrical industrial process-control equipment

This is equipment which controls one or more output quantities to specific values, with each value determined by manual setting, by local or remote programming, or by one or more input variables.

c) Electrical laboratory equipment

This is equipment which measures, indicates, monitors, inspects or analyses materials, or is used to prepare materials, and includes in vitro diagnostic (IVD) equipment.

This equipment may also be used in areas other than laboratories; examples include selftest IVD equipment to be used in the home and inspection equipment to be used to check people or material during transportation.

Equipment excluded from scope

This standard does not apply to equipment within the scope of:

a) IEC 60065 (Audio, video and similar electronic apparatus);

b) IEC 60204 (Safety of machinery – Electrical equipment of machines);

c) IEC 60335 (Household and similar electrical appliances);

d) IEC 60364 (Electrical installations of buildings);

e) IEC 60439 (Low-voltage switchgear and controlgear assemblies);

f) IEC 60601 (Medical electrical equipment);

g) IEC 60950 (Information technology equipment including electrical business equipment, except as specified in 1.1.3);

h) IEC 61558 (Power transformers, power supply units and similar);

i) IEC 61010-031 (Hand-held probe assemblies);

j) IEC 61243-3 (Live working – Voltage detectors – Part 3: Two-pole low-voltage type).

This group safety publication is primarily intended to be used as a product safety standard for the products mentioned in the scope, but shall also be used by technical committees in the preparation of its publications for products similar to those mentioned in the scope of this standard, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51.

NOTE If all or part of the equipment falls within the scope of one or more other Part 2 standards of IEC 61010 as well as within the scope of this standard, it will also need to meet the requirements of those other Part 2 standards.

aa) IEC 60034 (Rotating electrical machinery);

aa) contact with moving parts (see 7.3);

bb) LABORATORY CENTRIFUGE movement during any DISRUPTION (see 7.3.101);

cc) high energy chemical reaction after ROTOR DISRUPTION (see 7.7.2.2 l));

dd) ineffectiveness of BIOSEALS (see 13.101)

aa) additional precautions which may need to be observed when centrifuging materials which are flammable or explosive (see 5.4.101);

bb) additional precautions which may need to be observed when centrifuging materials that could react chemically with sufficient vigour to cause a HAZARD (see 5.4.101).

c) temperature 2 °C to 40 °C;

c) ambient temperatures below 2 °C or above 40 °C;


Edition : 17
File Size : 1 file , 1 MB
Number of Pages : 40
Published : 10/01/2017

History

CEI EN 61010-2-020
Published Date: 02/01/2019
Prescrizioni di sicurezza per apparecchi elettrici di misura, di controllo e da laboratorio Parte 2-020: Prescrizioni particolari per centrifughe da laboratorio
$23.7
CEI EN 61010-2-020
Published Date: 10/01/2017
Safety requirements for electrical equipment for measurement, control, and laboratory use Part 2-020: Particular requirements for laboratory centrifuges
$23.7
CEI EN 61010-2-020
Published Date: 06/01/2007
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-020: Particular requirements for laboratory centrifuges
$28.2

Related products

CEI 62-47
Published Date: 08/01/2004
Guida alle prove di accettazione e alle verifiche periodiche di sicurezza e di prestazione dei defibrillatori cardiaci con e senza monitor incorporato
$6
CEI EN IEC 60839-11-33
Published Date: 07/01/2022
Alarm and electronic security systems Part 11-33: Electronic access control systems - Access control configuration based on Web services
$105.6
CEI EN 61300-2-37
Published Date: 02/01/2017
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures Part 2-37: Tests - Cable bending for fibre optic closures
$11.7
CEI EN 50463-1
Published Date: 04/01/2018
Railway applications - Energy measurement on board trains Part 1: General
$15.9

Best-Selling Products

Laminar Flow Theory
Published Date: 04/01/1996
$9