Description:

Safety requirements for electrical equipment for measurement, control, and laboratory use Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$58.2
Need Help?
ENGLISH * W/D S/S BY CEI EN IEC 61010-2-032

Equipment included in scope

Replacement:

Replace the existing text with the following: This part of IEC 61010 specifies safety requirements for HAND-HELD and hand-manipulated current sensors described below.

These current sensors are for measuring, detecting or injecting current, or indicating current waveforms on circuits without physically opening the current path of the circuit being measured. They may be stand-alone current sensors or accessories to other equipment or parts of combined equipment (see Figure 101). These include measurement circuits which are part of electrical test and measurement equipment, laboratory equipment, or process control equipment. The existence of these current sensors and circuits in equipment requires additional protective means between the current sensor, the circuit and an OPERATOR.

NOTE 1 This part includes also the requirements of Part 2-030. Testing and measuring circuits that are not within the scope of this part are considered to be covered by the requirements of Part 1 or other parts 2s of IEC 61010, and then will also need to meet the requirements of these other parts with the exception of Part 2-030. Current clamp meters and similar currents sensors that have a primary purpose of measuring voltage on a live MAINS CIRCUIT are also within the scope of Part 2-033.

NOTE 2 Some current sensors are also known as current clamps and current probes.

Current sensors require hand manipulation before or after a test or measurement, but do not necessarily need to be HAND-HELD during the test or measurement.

NOTE 3 Some current sensors designed for portable use can also be used for fixed installations.

The following types of current sensors are covered:

a) Type A: a current sensor designed to be applied around or removed from UNINSULATED HAZARDOUS LIVE conductors. Type A current sensors have defined HAND-HELD or handmanipulated parts providing protection against electric shock from the conductor being measured, and also have protection against short-circuits between wires and busbars during clamping.

b) Type B: a current sensor which has protection against short-circuits between wires or busbars during clamping but without defined HAND-HELD or hand-manipulated parts which provide protection against electric shock during clamping. Additional protective means are necessary to avoid electric shock from HAZARDOUS LIVE conductors which cannot be deenergised during application or removal of the current sensor.

EXAMPLE 1 Flexible current sensors.

c) Type C: a current sensor without protection against short-circuits between wires or busbars during clamping. Type C current sensors are intended to be applied to or removed from UNINSULATED HAZARDOUS LIVE conductors or from non-limited-energy circuit conductors only when they are de-energised.

EXAMPLE 2 Split-core transducers.

d) Type D: a current sensor designed to be applied around or removed from insulated conductors or from limited-energy circuit conductors.

A Type D current sensor does not need protection against short-circuits during clamping and has no defined HAND-HELD or hand-manipulated parts providing protection against electric shock from the conductor being measured.

EXAMPLE 3 Current probes for oscilloscopes and earth leakage current detectors.

NOTE 4 All current sensors can also be used around insulated conductors. In this case, HAZARDS are limited to acceptable levels by the insulation of the conductors.


Edition : 13
File Size : 1 file , 1.1 MB
Number of Pages : 56
Published : 07/01/2013

History

CEI EN IEC 61010-2-032
Published Date: 07/01/2022
Safety requirements for electrical equipment for measurement, control and laboratory use Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement
$42.9
CEI EN 61010-2-032
Published Date: 07/01/2013
Safety requirements for electrical equipment for measurement, control, and laboratory use Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement
$58.2

Related products

CEI EN 50187
Published Date: 10/01/2023
High-voltage switchgear and controlgear - Gas-filled compartments of AC switchgear and controlgear with rated voltages above 1 kV up to and including 52 Kv
$9.6
CEI EN 60601-2-25
Published Date: 12/01/1996
Medical electrical equipment - Part 2: Particular requirements for the safety of electrocardiographs
$25.8
CEI IEC 62328-3
Published Date: 12/01/2022
Multimedia home server systems - Interchangeable volume/file structure adaptation for broadcasting receivers Part 3: Broadcasting system specific recording structure – ISDB
$32.7
CEI EN IEC 60721-3-0
Published Date: 02/01/2021
Classification of environmental conditions Part 3-0: Classification of groups of environmental parameters and their severities - Introduction
$9.9

Best-Selling Products

ISO/ASTM 51026:2015
Published Date: 07/15/2015
Practice for using the Fricke dosimetry system
$24.3
ISO/ASTM 51204:2004
Published Date: 08/01/2004
Practice for dosimetry in gamma irradiation facilities for food processing
$10.5
ISO/ASTM 51205:2009
Published Date: 01/01/2009
Practice for use of a ceric-cerous sulfate dosimetry system
ISO/ASTM 51205:2017
Published Date: 07/15/2015
Practice for use of a ceric-cerous sulfate dosimetry system
$20.4
ISO/ASTM 51261:2002
Published Date: 03/01/2002
Guide for selection and calibration of dosimetry systems for radiation processing
$12.3
ISO/ASTM 51261:2013
Published Date: 04/15/2013
Practice for calibration of routine dosimetry systems for radiation processing
$37.2