CEI EN 61010-2-040 PDF

CEI EN 61010-2-040 PDF

Name:
CEI EN 61010-2-040 PDF

Published Date:
03/01/2016

Status:
[ Revised ]

Description:

Safety requirements for electrical equipment for measurement, control, and laboratory use Part 2-040 Particular requirements for sterilizers and washer-disinfectors used to treat medical materials

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$21.9
Need Help?
ENGLISH * W/D S/S BY CEI EN IEC 61010-2-040

Equipment included 

This part of IEC 61010 specifies safety requirements for electrical equipment intended for sterilization, washing, and disinfection of medical materials in the medical, veterinary, pharmaceutical and laboratory fields, when used under the environmental conditions of 1.4. Examples of such equipment include the following:

a) sterilizers and disinfectors using steam, and/or hot water as the sterilant;

b) sterilizers and disinfectors using toxic gas, toxic aerosol or toxic vapour as the sterilant;

c) sterilizers and disinfectors using hot air or hot inert gas as the sterilant; and

d) washer disinfectors.

Equipment excluded from scope

NOTE IEC 60601-1 defines medical electrical equipment as follows:

Electrical equipment, provided with not more than one connection to a particular supply MAINS and intended by its manufacturer to be used in the diagnosis, treatment, or monitoring of a patient; and that makes physical or electrical contact with the patient or transfers energy to or from the patient or detects such energy transfer to or from the patient.

Add the following new second paragraph: This part of IEC 61010 does not apply to the following types of equipment:

aa) equipment for use in hazardous atmospheres (see IEC 60079) but does apply to an atmosphere created inside equipment by a flammable sterilizing agent (see 13.0);

bb) laboratory equipment for the heating of materials for other purposes than sterilization or disinfection (see IEC 61010-2-010);

cc) laundry equipment (see IEC 60335-2-4, IEC 60335-2-7, IEC 60335-2-11, and ISO 10472), unless designed for disinfecting medical materials;

dd) dishwashers (see IEC 60335-2-5 and IEC 60335-2-58).

Aspects included in scope

g) with the following new text:

g) liberated gases (including the non-intentional escape of toxic gas), pathogenic substances, explosion and implosion (see Clause 13).


Edition : 16
File Size : 1 file , 1.2 MB
Number of Pages : 44
Published : 03/01/2016

History

CEI EN IEC 61010-2-040
Published Date: 09/01/2022
Safety requirements for electrical equipment for measurement, control and laboratory use Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
$28.2
CEI EN 61010-2-040
Published Date: 03/01/2016
Safety requirements for electrical equipment for measurement, control, and laboratory use Part 2-040 Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
$21.9
CEI EN 61010-2-040
Published Date: 10/01/2005
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-040: Particular requirements for sterilizers and washerdisinfectors used to treat medical materials
$26.1

Related products

CEI UNI EN 16212
Published Date: 10/01/2012
Energy Efficiency and Savings Calculation Top-down and Bottom-up Methods
$26.1
CEI 15-90
Published Date: 06/01/1997
Guida per la determinazione degli effetti della radiazione ionizzante su materiali isolanti - Parte 2: Procedure per l'irraggiamento e le prove
$9.3
CEI EN 60695-1-11
Published Date: 05/01/2016
Fire hazard testing Part 1-11: Guidance for assessing the fire hazard of electrotechnical products - Fire hazard assessment
$31.5
CEI EN 61000-4-25
Published Date: 07/01/2003
Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems
$50.1

Best-Selling Products