CEI EN 62772 PDF

CEI EN 62772 PDF

Name:
CEI EN 62772 PDF

Published Date:
06/01/2017

Status:
[ Revised ]

Description:

Composite Hollow Core Station Post Insulators for substations with a.c. voltage greater than 1 000 V and d.c. voltage greater than 1 500 V - Definitions, test methods and acceptance criteria

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$16.8
Need Help?
BILINGUAL

This International Standard applies to composite hollow core station post insulators consisting of a load-bearing insulating tube (core) made of resin impregnated fibres an insulating filler material (e.g. solid, liquid, foam, gaseous – pressurized or unpressurized), a housing (outside the insulating tube) made of polymeric material (for example silicone or ethylene-propylene) and metal fixing devices at the ends of the insulating tube. Composite hollow core station post insulators as defined in this standard are intended for general use in substations in both, outdoor and indoor environments, operating with a rated AC voltage greater than 1 000 V and a frequency not greater than 100 Hz or for use in direct current systems with a rated voltage greater than 1 500 V.

The object of this standard is:

– to define the terms used;

– to prescribe test methods;

– to prescribe acceptance criteria.

All the tests in this standard, apart from the thermal-mechanical test, are performed at normal ambient temperature. This standard does not prescribe tests that may be characteristic of the apparatus of which the composite hollow core station post insulator ultimately may form a part. Further technical input is required in this area.

NOTE 1 "Pressurized" means a permanent gas or liquid pressure greater than 0,05 MPa (0,5 bar) gauge. The gas can be dry air or inert gases, for example sulphur hexafluoride, nitrogen, or a mixture of such gases.

NOTE 2 "Unpressurized" means a gas or liquid pressure smaller than or equal to 0,05 MPa (0,5 bar) gauge.


Edition : 17#
File Size : 1 file , 1.9 MB
Number of Pages : 32
Published : 06/01/2017

History

CEI EN IEC 62772
Published Date: 04/01/2024
Composite hollow core station post insulators for substations with a.c. voltage greater than 1000 V and d.c. voltage greater than 1500 V - Definitions, test methods and acceptance criteria
$22.5
CEI EN 62772
Published Date: 06/01/2017
Composite Hollow Core Station Post Insulators for substations with a.c. voltage greater than 1 000 V and d.c. voltage greater than 1 500 V - Definitions, test methods and acceptance criteria
$16.8

Related products

CEI EN IEC 62646
Published Date: 03/01/2020
Nuclear power plants - Control rooms - Computer-based procedures
$31.5
CEI EN 50131-2-5
Published Date: 09/01/2009
Alarm systems - Intrusion and hold-up systems Part 2-5: Requirements for combined passive infrared and ultrasonic detectors
$44.1
CEI EN IEC 61496-1
Published Date: 06/01/2021
Safety of machinery - Electro-sensitive protective equipment Part 1: General requirements and tests
$39.3
CEI EN 61249-2-1
Published Date: 07/01/2005
Materials for printed boards and other interconnecting structures - Part 2-1: Reinforced base material, clad and unclad - Phenolic cellulose paper reinforced laminate sheets, economic grade, copper clad
$12.9

Best-Selling Products

Vitamins and Minerals Handbook
Published Date: 04/01/2001
$3.9