CEI EN IEC 60601-2-19 PDF

CEI EN IEC 60601-2-19 PDF

Name:
CEI EN IEC 60601-2-19 PDF

Published Date:
04/01/2022

Status:
[ Active ]

Description:

Medical electrical equipment Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$27.3
Need Help?
ENGLISH

This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT INCUBATORS, as defined in 201.3.209, also referred to as ME EQUIPMENT.

If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.

HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document, except in 7.2.13 and 8.4.1 of the general standard.

NOTE See also 4.2 of the general standard.

This particular standard specifies safety requirements for INFANT INCUBATORS, but alternate methods of compliance with a specific clause, by demonstrating equivalent safety, will not be judged as non-compliant, if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device.

This particular standard does not apply to:

– INFANT TRANSPORT INCUBATORS; for information, see IEC 60601-2-20 [1]2;

– INFANT RADIANT WARMERS; for information, see IEC 60601-2-21 [2];

– devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use; for information, see IEC 60601-2-35 [3];

– INFANT PHOTOTHERAPY EQUIPMENT; for information see IEC 60601-2-50 [4].

SKIN TEMPERATURE SENSORS which are applied to operate a BABY CONTROLLED INCUBATOR including the displayed value are not considered to be a CLINICAL THERMOMETER in the sense of the particular standard ISO 80601-2-56.

2 Figures in square brackets refer to the Bibliography.


Edition : 22#
File Size : 1 file , 2.7 MB
Number of Pages : 48
Published : 04/01/2022

History

CEI EN IEC 60601-2-19
Published Date: 04/01/2022
Medical electrical equipment Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators
$27.3
CEI EN 60601-2-19
Published Date: 03/01/2011
Medical electrical equipment Part 2: Particular requirements for the basic safety and essential performance of infant incubators
$46.5

Related products

CEI EN 60745-2-22
Published Date: 06/01/2012
Hand-held motor-operated electric tools - Safety Part 2: Particular requirements for cut-off machines
$35.4
CEI 62-46
Published Date: 02/01/1998
Guida all'utilizzo dei defibrillatori cardiaci e defibrillatori cardiaci con monitor incorporato
$7.8
CEI UNI EN ISO/IEC 27038
Published Date: 06/01/2017
Information technology - Security techniques - Specification for digital redaction
$13.2
CEI 81-29
Published Date: 11/01/2020
Linee guida per l’applicazione delle Norme CEI EN 62305
$26.1

Best-Selling Products

DOT 23 CFR PART 625
Published Date: 04/01/2020
DESIGN STANDARDS FOR HIGHWAYS
$9
DOT 23 CFR PART 645
Published Date: 04/01/2019
UTILITIES
$10.8
DOT 23 CFR PART 655
Published Date: 04/01/2018
TRAFFIC OPERATIONS
$9.3
DOT 33 CFR PART 127
Published Date: 07/01/2019
WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS
$11.7
DOT 33 CFR PART 154
Published Date: 07/01/2017
FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK
$18.3
DOT 33 CFR PART 154
Published Date: 07/01/2019
FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK
$18.3