CEI EN IEC 60939-3 PDF

CEI EN IEC 60939-3 PDF

Name:
CEI EN IEC 60939-3 PDF

Published Date:
05/01/2024

Status:
[ Active ]

Description:

Passive filter units for electromagnetic interference suppression – Part 3: Passive filter units for which safety tests are appropriate

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$50.4
Need Help?

This part of IEC 60939 covers passive filters used to attenuate unwanted radio-frequency signals (such as noise or interference) generated from electromagnetic sources.

Both single and multi-channel filters within one enclosure or which are built on a printed circuit board forming a compact entity are included within the scope of this document.

Filters constructed of capacitive elements where the inductance is inherent in the construction of the filter are within the scope of this document. Similarly, filters constructed of inductive elements where the capacitance is inherent in the construction of the filter are also within the scope of this document. It is up to the manufacturer to state whether a given component is to be designed as a capacitor, an inductor or a filter. Filters can include also other components such as resistors and/or varistors or similar components.

This document applies to passive filter units for electromagnetic interference suppression for which safety tests are appropriate. This implies that filters specified according to this document will either be connected to mains supplies, when compliance with the mandatory tests of Table B.1 is necessary, or used in other circuit positions where the equipment specification specifies that some or all of these safety tests are required.

This document applies to passive filter units, which will be connected to an AC mains or other supply (DC or AC) with a nominal voltage not exceeding 1 000 V AC, with a nominal frequency not exceeding 400 Hz, or 1 500 V DC.

NOTE For AC use, IEC 60384-14 applies to capacitors which will be connected to AC mains with a nominal frequency not exceeding 100 Hz.

This document covers appliance filters (US) but does not cover facility filters, cord-connected filters or direct plug-in filters. These other filters will be covered by another sectional specification.


Edition : 24#
File Size : 1 file , 2.6 MB
Number of Pages : 90
Published : 05/01/2024

History

CEI EN IEC 60939-3
Published Date: 05/01/2024
Passive filter units for electromagnetic interference suppression – Part 3: Passive filter units for which safety tests are appropriate
$50.4
CEI EN 60939-3
Published Date: 07/01/2016
Passive filter units for electromagnetic interference suppression Part 3: Passive filter units for which safety tests are appropriate
$34.8

Related products

CEI EN IEC 63327
Published Date: 03/01/2022
Macchine automatiche per il trattamento dei pavimenti per uso collettivo - Norme particolari
$27.3
CEI EN 62129
Published Date: 08/01/2006
Calibration of optical spectrum analyzers
$39
CEI EN 61310-3
Published Date: 10/01/2008
Safety of machinery - Indication, marking and actuation Part 3: Requirements for the location and operation of actuators
$15.9
CEI EN IEC 61058-2-1
Published Date: 08/01/2022
Interruttori per apparecchi Parte 2-1: Prescrizioni particolari per interruttori per cavi flessibili
$17.7

Best-Selling Products

AAMI/ISO 10993-1:2003
Published Date: 12/01/2003
Biological Evaluation of Medical Devices Part 1: Evaluation and Testing
$26.4
AAMI/ISO 10993-1:2009 Erratum
Published Date: 06/10/2013
Erratum for Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
Free Download
AAMI/ISO 10993-1:2009/(R)2013
Published Date: 09/03/2009
Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process; Includes Erratum (2013)
AAMI/ISO 10993-1:2018
Published Date: 04/27/2020
Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
$82.5
AAMI/ISO 10993-10:2010/(R)2014
Published Date: 09/04/2010
Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitization
$82.5
AAMI/ISO 10993-11:2006/(R)2014
Published Date: 10/19/2006
Biological evaluation of medical devices - Part 11: Tests for systemic toxicity