Description:

Safety requirements for electrical equipment for measurement, control and laboratory use Part 2-091: Particular requirements for cabinet X-ray systems

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$23.7
Need Help?
ENGLISH

Equipment included in scope

This part of IEC 61010 specifies general safety requirements for the following types of electrical equipment and their accessories, wherever they are intended to be used.

a) Electrical test and measurement equipment

This is equipment which by electromagnetic means tests, measures, indicates or records one or more electrical or physical quantities, also non-measuring equipment such as signal generators, measurement standards, power supplies for laboratory use, transducers, transmitters, etc.

NOTE 1 This includes bench-top power supplies intended to aid a testing or measuring operation on another piece of equipment. Power supplies intended to power equipment are within the scope of IEC 61558 (see 1.1.2 h)).

This standard also applies to test equipment integrated into manufacturing processes and intended for testing manufactured devices.

NOTE 2 Manufacturing test equipment is likely to be installed adjacent to and interconnected with industrial machinery in this application.

b) Electrical industrial process-control equipment

This is equipment which controls one or more output quantities to specific values, with each value determined by manual setting, by local or remote programming, or by one or more input variables.

c) Electrical laboratory equipment

This is equipment which measures, indicates, monitors, inspects or analyses materials, or is used to prepare materials, and includes in vitro diagnostic (IVD) equipment.

This equipment may also be used in areas other than laboratories; examples include selftest IVD equipment to be used in the home and inspection equipment to be used to check people or material during transportation.

This part of IEC 61010 specifies particular safety requirements for cabinet X-ray systems, which fall under any of categories a), b) or c) below.

Equipment covered by this document can be both PROTECTED EQUIPMENT or PARTIALLY PROTECTED EQUIPMENT, with X-ray generator voltage up to 500 kV.

A cabinet X-ray system is a system that contains an X-ray tube installed in a cabinet, which, independently of existing architectural structures except the floor on which it may be placed, is intended to contain at least that portion of a material being irradiated, provide radiation attenuation and prevent operator access to the radiation beam, during generation of X-radiation.

These cabinet X-ray systems are used in industrial, commercial, and public environments, for example, to inspect materials, to analyse materials, and to screen baggage.

Equipment excluded from scope

This standard does not apply to equipment within the scope of:

a) IEC 60065 (Audio, video and similar electronic apparatus);

b) IEC 60204 (Safety of machinery – Electrical equipment of machines);

c) IEC 60335 (Household and similar electrical appliances);

d) IEC 60364 (Electrical installations of buildings);

e) IEC 60439 (Low-voltage switchgear and controlgear assemblies);

f) IEC 60601 (Medical electrical equipment);

g) IEC 60950 (Information technology equipment including electrical business equipment, except as specified in 1.1.3);

h) IEC 61558 (Power transformers, power supply units and similar);

i) IEC 61010-031 (Hand-held probe assemblies);

j) IEC 61243-3 (Live working – Voltage detectors – Part 3: Two-pole low-voltage type).

aa) Equipment intended to apply X-radiation to humans or animals;

bb) Equipment incorporating an X-ray tube but not incorporating complete shielding against X-radiation HAZARDS, such as:

– equipment intended to be used within a shielded room which excludes personnel during operation;

– equipment intended to be used with separate portable or temporary shielding;

– equipment intended to produce an emerging beam of X-radiation.

Computing equipment

This standard applies only to computers, processors, etc. which form part of equipment within the scope of this standard or are designed for use exclusively with the equipment.

NOTE Computing devices and similar equipment within the scope of IEC 60950 and conforming to its requirements are considered to be suitable for use with equipment within the scope of this standard. However, some of the requirements of IEC 60950 for resistance to moisture and liquids are less stringent than those in this standard (see 5.4.4 second paragraph))


Edition : 22#
File Size : 1 file , 2.7 MB
Number of Pages : 40
Published : 04/01/2022

History

CEI EN IEC 61010-2-091
Published Date: 04/01/2022
Safety requirements for electrical equipment for measurement, control and laboratory use Part 2-091: Particular requirements for cabinet X-ray systems
$23.7
CEI EN 61010-2-091
Published Date: 07/01/2014
Safety requirements for electrical equipment for measurement, control and laboratory use Part 2-091: Particular requirements for cabinet x-ray systems
$17.4

Related products

CEI EN 60335-2-67
Published Date: 10/01/2013
Household and similar electrical appliances - Safety Part 2: Particular requirements for floor treatment machines for commercial use
$65.7
CEI EN 61747-5-3
Published Date: 11/01/2011
Liquid crystal display devices Part 5-3: Environmental, endurance and mechanical test methods - Glass strength and reliability
$22.8
CEI EN IEC 62439-3
Published Date: 10/01/2022
Industrial communication networks - High availability automation networks Part 3: Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR)
$142.2

Best-Selling Products