CEI EN IEC 62056-3-1 PDF

CEI EN IEC 62056-3-1 PDF

Name:
CEI EN IEC 62056-3-1 PDF

Published Date:
05/01/2022

Status:
[ Active ]

Description:

Electricity metering data exchange - The DLMS/COSEM suite Part 3-1: Use of local area networks on twisted pair with carrier signalling

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$76.2
Need Help?
ENGLISH

This part of IEC 62056 describes two sets of profiles: the first set of profiles allows a bidirectional communication between a client and a server. This set of profiles is made of three profiles allowing local bus data exchange with stations either energized or not. For non-energized stations, the bus supplies energy for data exchange. Three different profiles are supported:

• base profile: this three-layer profile provides remote communication services;

NOTE 1 This first profile was published in IEC 61142:1993 and became known as the Euridis standard.

• profile with DLMS: this profile allows using DLMS services as specified in IEC 61334-4-41;

NOTE 2 This second profile was published in IEC 62056-31:1999.

• profile with DLMS/COSEM: this profile allows using the DLMS/COSEM Application layer and the COSEM object model as specified in IEC 62056-5-3 and in IEC 62056-6-2 respectively.

The three profiles use the same physical layer and they are fully compatible, meaning that devices implementing any of these profiles can be operated on the same bus. The transmission medium is twisted pair using carrier signalling and it is known as the Euridis Bus.

The second set of profiles allows unidirectional communication between a given Energy Metering device and a Customer Energy Management System. This second set is made up of three profiles.

Subclause 4.2.1 to Clause 8 included specify the bidirectional communication using twisted pair signalling and Clause 9 to 9.5 the unidirectional communication using twisted pair signalling.


Edition : 22#
File Size : 1 file , 4.2 MB
Number of Pages : 136
Published : 05/01/2022

History

CEI EN IEC 62056-3-1
Published Date: 05/01/2022
Electricity metering data exchange - The DLMS/COSEM suite Part 3-1: Use of local area networks on twisted pair with carrier signalling
$76.2
CEI EN 62056-3-1
Published Date: 07/01/2014
Electricity metering data exchange - The DLMS/COSEM suite Part 3-1: Use of local area networks on twisted pair with carrier signalling
$78.9

Related products

CEI EN 62321-3-2
Published Date: 07/01/2016
Determination of certain substances in electrotechnical products Part 3-2: Screening - Total bromine in polymers and electronics by Combustion - Ion Chromatography
$15.6
CEI EN 50377-7-2
Published Date: 09/01/2005
Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications Part 7-2: LC-PC duplex terminated on IEC 60793-2 category B1.1 singlemode fibre
$22.2
CEI EN 61300-2-31
Published Date: 12/01/1997
Fibre optic interconnecting devices and passive components Basic test and measurement procedures - Part 2-31: Tests - Nuclear radiation
$11.7
CEI EN IEC 61000-4-18
Published Date: 11/01/2022
Compatibilità elettromagnetica (EMC) Parte 4-18: Tecniche di prova e di misura - Prova d'immunità alle onde oscillatorie smorzate
$39.3

Best-Selling Products

Handbook of Practical Gear Design
Published Date: 09/01/1994
$18
Industrial Fire Protection Handbook
Published Date: 04/01/1992
$19.5
New Fibers
Published Date: 10/01/1997
$48
The Drinking Water Handbook
Published Date: 01/01/2000
$24