General
a) This part of IEC 62282 covers micro fuel cell power systems and fuel cartridges that are wearable or easily carried by hand, providing direct current outputs that do not exceed 60 V DC and power outputs that do not exceed 240 VA. Portable fuel cell power systems that provide output levels that exceed these electrical limits are covered by IEC 62282-5-100.
b) Externally accessible circuitry is therefore considered to be ES1 energy source as defined in IEC 62368-1, and as limited power source if further compliance with IEC 62368-1:2023, Annex Q is demonstrated. Micro fuel cell power systems that have internal circuitry exceeding 60 V DC or 240 VA are addressed with the separate criteria of IEC 62368-1.
c) This document covers micro fuel cell power systems and fuel cartridges. This document establishes the requirements for micro fuel cell power systems and fuel cartridges to ensure a reasonable degree of safety for normal use, reasonably foreseeable misuse, and cargo and consumer transportation and storage of such items. Fuel cartridges refilled by the manufacturer or by trained technicians are covered by this document. The fuel cartridges covered by this document are not intended to be refilled by the consumer.
d) Micro fuel cell power systems and fuel cartridges that are covered by this document are not intended for use in hazardous areas as defined by IEV 426-03-01.
Fuels and technologies covered
a) A micro fuel cell power system block diagram is shown in Figure 1.
b) This document, including all annexes, apply to micro fuel cell power systems and fuel cartridges as defined in 1.1 above.
c) Clause 4 to Clause 8 cover the general safety requirements for all micro fuel cell power systems. IEC 62282-6-101 together with the appropriate technology specific parts shown in Table 1 cover the requirements for the specific technologies in the IEC 62282-6-1XX series.
Equivalent level of safety
a) The requirements of this document are not intended to constrain innovation. The manufacturer can consider fuels, materials, designs or constructions not specifically dealt with in this document. These alternatives can be evaluated as to their ability to yield levels of safety equivalent to those specified in this document.
b) It is understood that all micro fuel cell power systems and fuel cartridges comply with applicable country and local requirements including, but not limited to, those concerning transportation, child-resistance and storage, where required.
| Edition : | 24# |
| File Size : | 1 file , 1 MB |
| Number of Pages : | 64 |
| Published : | 05/01/2024 |