Name:
CEI EN IEC 62321-11 PDF
Published Date:
04/01/2024
Status:
[ Active ]
Publisher:
Comitato Elettrotecnico Italiano
This part of IEC 62321 specifies two different techniques for the determination of tris(2-chloroethyl) phosphate (TCEP) in plastics, the GC-MS or LC-MS method, both of which are applicable to quantitative analysis.
These two techniques are applicable to use with polyurethane, polyvinylchloride, and polyethylene materials containing TCEP between 200 mg/kg to 2 000 mg/kg.
These test methods do not apply to plastic materials having a processing temperature higher than 230 °C.
GC-MS using a pyrolyser/thermal desorption accessory (Py/TD-GC-MS) technique is described in Annex A and can be used for the screening of TCEP in plastics.
NOTE TCEP starts thermal decomposition at approximately 230 °C. Polymer types that have a processing temperature into shapes of plastics (e.g. pellets, moulded parts or sheets) not exceeding the decomposition temperature can contain TCEP.
| Edition : | 24# |
| File Size : | 1 file , 2.4 MB |
| Number of Pages : | 45 |
| Published : | 04/01/2024 |