This part of IEC 60287 is solely applicable to the conditions of steady-state operation of cables at all alternating voltages, and direct voltages up to 5 kV, buried directly in the ground, in ducts, in troughs or in steel pipes, both with and without partial drying-out of the soil, as well as cables in air. The term "steady state" is intended to mean a continuous constant current (100 % load factor) just sufficient to produce asymptotically the maximum conductor temperature, the surrounding ambient conditions being assumed constant.

This part of IEC 60287 provides formulae for thermal resistance. The formulae given are essentially literal and designedly leave open the selection of certain important parameters.

These may be divided into three groups:

– parameters related to construction of a cable (for example, thermal resistivity of insulating material) for which representative values have been selected based on published work;

– parameters related to the surrounding conditions which may vary widely, the selection of which depends on the country in which the cables are used or are to be used;

– parameters which result from an agreement between manufacturer and user and which involve a margin for security of service (for example, maximum conductor temperature).

Equations given in this part of IEC 60287 for calculating the external thermal resistance of a cable buried directly in the ground or in a buried duct are for a limited number of installation conditions. Where analytical methods are not available for calculation of external thermal resistance finite element methods may be used. Guidance on the use of finite element methods for calculating cable current ratings is given in IEC TR 62095.


Edition : 18
File Size : 1 file , 1.8 MB
Number of Pages : 49
Published : 10/01/2018

History


Related products

CEI EN 61184
Published Date: 07/01/2010
Bayonet lampholders
$15.3
CEI EN 50318
Published Date: 07/01/2019
Railway applications - Current collection systems - Validation of simulation of the dynamic interaction between pantograph and overhead contact line
$62.1
CEI EN 175201-804
Published Date: 05/01/2000
Detail Specification: Circular connectors - Round contacts, size diameter 1,6 mm, threaded coupling
$28.2
CEI EN 60512-25-2
Published Date: 04/01/2003
Connectors for electronic equipment - Tests and measurements - Part 25-2: Test 25b: Attenuation (insertion loss)
$12.3

Best-Selling Products