CGA G-4.4 PDF

CGA G-4.4 PDF

Name:
CGA G-4.4 PDF

Published Date:
08/25/2020

Status:
Active

Description:

Oxygen Pipeline and Piping Systems

Publisher:
Compressed Gas Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$92.4
Need Help?

The scope of this publication is for metal oxygen pipelines, distribution piping systems, and gaseous oxygen piping on an air separation plant external to the coldbox. The scope is limited to gaseous oxygen with a temperature range between –22 °F and 400 °F (–30 °C and 200 °C), pressures up to 3000 psi (21 MPa), and a dew point of –22 °F (–30 °C) or less depending on local conditions. Although it is possible to safely use oxygen at higher temperatures and/or pressures, such applications are beyond the scope of this publication. In these cases, additional materials testing and/or a risk assessment, as appropriate to the application, shall be undertaken.

This publication does not apply to the following processes:

  • oxygen cylinder filling plants;
  • medical oxygen piping installations;
  • coldbox internal piping;
  • oxygen compressor units;
  • liquid oxygen vaporizers;
  • bulk oxygen facilities (liquid or high pressure gas) at the customer’s site up to the point where gas enters the distribution systems; or
  • piping on specialized equipment and machines such as scarfing, jet piercing, etc.

The use of nonmetal piping for oxygen-enriched gases in production plants, transmission systems, or distribution systems is outside the scope of this publication and requires a specific risk assessment and precautions.

The purpose of this publication is to further the understanding of those engaged in the safe design, operation, and maintenance of gaseous oxygen transmission and distribution systems. It is not intended to be a mandatory standard or code.

Some of the practices represent conservative compromises and not all situations are described. The designer is cautioned that this publication is not a complete design handbook and does not do away with the need for competent engineering judgment and interpretation. It is suggested that the user review any special problems or concerns with their oxygen supplier who should be able to provide advice and guidance.


Edition : 6th
File Size : 1 file , 1.1 MB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 80
Published : 08/25/2020

History

CGA G-4.4
Published Date: 08/25/2020
Oxygen Pipeline and Piping Systems
$92.4
CGA G-4.4
Published Date: 10/26/2012
Oxygen Pipeline and Piping Systems
CGA G-4.4
Published Date: 12/04/2003
Industrial Practices for Gaseous Oxygen Transmission and Distribution Piping Systems

Related products

CGA G-2.2
Published Date: 06/28/2021
Guideline Method for Determining Minimum of 0.2% Water in Anhydrous Ammonia
$15.6
CGA G-6.14
Published Date: 11/30/2023
Standard for Carbon Dioxide Monitoring in Near Consumer and Industrial Applications
$31.2
CGA M-24
Published Date: 04/23/2024
Standard for Mitigating Oxygen Hazards in the Health Care Environment
$5.7

Best-Selling Products

UNE-CEN/TR 12401:2009 IN
Published Date: 10/28/2009
Dentistry - Guidance on the classification of dental devices and accessories
UNE-CEN/TR 12566-5:2010 IN
Published Date: 01/20/2010
Small wastewater treatment systems up to 50 PT - Part 5: Pre-treated Effluent Filtration systems
UNE-CEN/TR 13445-9:2009 IN
Published Date: 10/28/2009
Unfired pressure vessels - Part 9: Conformance of the EN 13445 series to ISO 16528
UNE-CEN/TR 13480-7:2003
Published Date: 01/17/2003
Metallic industrial piping . Part 7: Guidance on the use of conformity assessment procedures.
UNE-CEN/TR 13548:2007 IN
Published Date: 09/26/2007
General rules for the design and installation of ceramic tiling
UNE-CEN/TR 13688:2008 IN
Published Date: 12/22/2008
Packaging - Material recycling - Report on requirements for substances and materials to prevent a sustained impediment to recycling