CGA TR-7 PDF

CGA TR-7 PDF

Name:
CGA TR-7 PDF

Published Date:
09/28/2023

Status:
Active

Description:

Methodology to Determine Piping Failure Rates for Nontoxic Cryogenic Industrial Gas Supply Systems with Pipe Size Up to 6 Inches

Publisher:
Compressed Gas Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
cga-tr-7_2575595

Choose Document Language:
62.70 €
Need Help?

This technical report applies to 300 series austenitic stainless steel piping up to and including 6 inches in diameter, suitable for nontoxic cryogenic service, and where the design pressure stress of pipe and tube does not exceed one half of the basic allowable stress.

Small scale industrial gas installations, and in particular ones for cryogenic service, need reasonable equipment failure rates to drive risk informed frameworks for siting and guideline setbacks. Current failure rate guidance does not fit well for small scale and is unnecessarily conservative. The study of recent efforts in this area demonstrates interest but no useful guidance on approaches.

Such guidance should be practical in its application and transparent in its design basis. The publicly available Hydrocarbon Release Database (HSE Hydrocarbon Release Database, www.hse.gov.uk/offshore/statistics) (HCRD) for leak rates is used to generate a universal failure rate equation that has small scale and cryogenic considerations included.

Additionally, a simplified approach to estimate equipment limits is developed that allows for quick estimates of system aggregate risks using an equivalent length approach.

When compared to traditionally approaches to risk-informed methods, the proposed method simplifies the number of iterations required, improves both the accuracy, and reduces the subjectivity.


Edition : 1st
File Size : 1 file , 5.6 MB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 60
Published : 09/28/2023

History


Related products

CGA TR-2 (R2022)
Published Date: 04/01/2004
High Pressure Steel Cylinders In Service Performance
105.60 €
CGA TR-3
Published Date: 08/09/2023
The Impact of Ambient Air Contaminants on Validation Requirements for the Air Separation Process
28.50 €
CGA M-27
Published Date: 08/24/2021
Guideline for Complying with Data Integrity Regulatory Expectations
9.60 €
CGA TR-5
Published Date: 09/24/2021
Nitrosamine Impurities in Nitrous Oxide and other Medical Gases (Includes 11/23/2021 Correction)
5.40 €

Best-Selling Products

AENOR EA 0007
Published Date: 09/07/2016
Requisitos del sistema de seguimiento y agregación de los precios del papel para reciclar.
12.90 €
AENOR EA 0014
Published Date: 02/14/2003
Marcado por impresión de los elementos calefactores que utilizan cable calefactor según la Norma UNE 21155-1.
5.40 €
AENOR EA 0032
Published Date: 07/11/2007
Equipos estabilizadores de tensión y reductores de flujo luminoso en cabecera de línea. Requisitos generales y de seguridad
23.70 €
AENOR EA 0039
Published Date: 02/04/2009
Cables multiconductores de tensión asignada 0,6/1 kV no propagadores del incendio, aislados con polietileno reticulado y con cubierta de poliolefina, para utilizar como instalación fija en circuitos de control.
18.90 €
AENOR EA 0042
Published Date: 12/23/2014
Aparamenta de baja tensión. Equipos auxiliares. Conjuntos de bloques de conexión para la verificación de contadores de energía.
22.20 €
AENOR EA 0051
Published Date: 12/23/2014
Cables eléctricos de distribución con aislamiento extruido, de tensión asignada desde 3,6/6 (7,2) kV hasta 20,8/36 (42) kV inclusive. Cables unipolares y unipolares reunidos con aislamiento de HPTE. Cables con cubierta de compuesto de poliolefina (tipo 1, tipo 2 y tipo 3)
22.20 €