CSA 2.33:19/ANSI Z21.88:19 PDF

CSA 2.33:19/ANSI Z21.88:19 PDF

Name:
CSA 2.33:19/ANSI Z21.88:19 PDF

Published Date:
11/01/2019

Status:
Active

Description:

Vented gas fireplace heaters, Includes Errata (2021)

Publisher:
CSA Group

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$251.4
Need Help?
Preface:

This is the ninth edition of CSA/ANSI Z21.88 • CSA 2.33, Vented gas fireplace heaters. It supersedes the previous editions published in 2017, 2016, 2014, 2009, 2005, 2002, 2000, and 1998.

Scope:

1.1
This Standard applies to newly produced vented gas fireplace heaters (see Clause 3, Definitions), hereinafter referred to as appliance(s), constructed entirely of new, unused parts and materials, and having input ratings up to and including 400,000 Btu/hr (117 228 W):
a) for use with natural gas;
b) for use with propane;
c) direct vent appliances for manufactured home (USA only) or mobile home OEM installation convertible for use with natural gas and propane when provision is made for simple conversion from one gas to the other [see Clause 4.1.4a) and b)];
d) direct vent appliances for manufactured home (USA only) or mobile home aftermarket installation for use with natural gas only or propane gas only [see Clause 4.1.4b)];
e) direct vent appliances for recreational vehicle installation for use with propane gas only [see Clause 4.1.4c)];
f) direct vent appliances for recreational vehicle installation only convertible for use with natural gas and propane gas when provision is made for the simple conversion from one gas to the other [see Clause 4.1.4c)]; and
g) for direct vent appliances for manufactured home (USA only) or mobile home OEM installation for use with propane gas only [see Clause 4.1.4a)].

The construction of vented gas fireplace heaters and vented gas fireplace heaters with cooling units for use with the above-mentioned gases is covered under Clause 4, Construction.

The performance of vented gas fireplace heaters and vented gas fireplace heaters with cooling units for use with the above-mentioned gases is covered under Clause 5, Performance.

1.2
Clauses 4and 5cover all vented gas fireplace heaters. In addition, Clauses 6and 7address the requirements specific to vented condensing gas fireplace heaters.

1.3
Annex A, Automatic intermittent pilot ignition systems or on-demand pilot ignition systems for field installation, includes provisions for newly produced (optional) automatic intermittent pilot ignition systems and on-demand pilot ignition systems (see Clause 3, Definitions), constructed entirely of new, unused parts and materials, to be adapted in the field to an appliance equipped with an existing continuous pilot burner and which has been examined and tested for compliance with this Standard when installed on the appliance.

1.4
If a value for measurement given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification.

1.5
All references to "psi" throughout this Standard are to be considered gauge pressures, unless otherwise specified.

1.6
Clause 9, Items unique to the United States, contains provisions that are unique to the United States.

1.7
Clause 10, Items unique to Canada, contains provisions that are unique to Canada.

1.8
This Standard also applies to appliances with draft hoods that are factory-equipped with automatic vent damper devices (see Clause 3, Definitions), hereinafter referred to as vent damper devices.

1.9
Special construction provisions applicable to vented gas fireplace heaters designed for use with an optional design-certified conversion kit are outlined under Annex B, Provisions for listed gas appliance conversion kits (optional).

1.10
Clause 2, Reference publications, contains a list of standards specifically referenced in this Standard and sources from which they may be obtained.

1.11
In this Standard, "shall" is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition : 9th
File Size : 1 file , 3.5 MB
ISBN(s) : 9781488322396
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 274
Product Code(s) : 2427668, 2427668
Published : 11/01/2019

History

CSA 2.33:19/ANSI Z21.88:19
Published Date: 11/01/2019
Vented gas fireplace heaters, Includes Errata (2021)
$251.4
CSA ANSI Z21.88-2017/CSA 2.33-2017
Published Date: 12/01/2017
Vented Gas Fireplace Heaters
$195
CSA ANSI Z21.88-2014/CSA 2.33-2014
Published Date: 02/01/2014
Vented Gas Fireplace Heaters
$196.8
CSA ANSI Z21.88-2009/CSA 2.33-2009
Published Date: 04/01/2009
Vented Gas Fireplace Heaters
$274.8
CSA ANSI Z21.88-2005/CSA 2.33-2005
Published Date: 12/01/2005
Vented Gas Fireplace Heaters
$312
CSA ANSI Z21.88-2002/CSA 2.33-2002
Published Date: 03/01/2002
Vented Gas Fireplace Heaters
$207.9

Related products

CSA ANSI Z21.40.1-1996 (R2022)/CGA 2.91-M96 (R2022)
Published Date: 11/01/2000
Gas-Fired, Heat Activated Air Conditioning and Heat Pump Appliances
$260.7
CSA /ANSI Z21.42:24/CSA 2.15:24
Published Date: 02/29/2024
Gas-fired domestic illuminating appliances
$150

Best-Selling Products

NAPM IT1.27
Published Date: 01/01/1994
Recording Instruments - Spooling Requirements
NAPM IT1.54
Published Date: 01/01/1994
Photography (Papers) - Rolls for Photocomposition - Dimensions - WITDRAWN - no S/S document
NAPM IT1.72
Published Date: 01/01/1997
Graphic Arts Sheet and Roll Film - Dimensions
NAPM IT9.1-1996
Published Date: 01/01/1996
IMAGING MEDIA (FILM) - SILVER-GELATIN TYPE - SPECIFICATIONS FOR STABILITY
NAPM IT9.22
Published Date: 01/01/1996
Imaging Materials - Processed Photographic Films - Methods for Determining Scratch Resistance