CSA 2.37-2014/ANSI Z83.26-2014 (R2019) PDF

CSA 2.37-2014/ANSI Z83.26-2014 (R2019) PDF

Name:
CSA 2.37-2014/ANSI Z83.26-2014 (R2019) PDF

Published Date:
06/01/2014

Status:
Active

Description:

Gas-Fired Outdoor Infrared Patio Heaters

Publisher:
CSA Group

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$135.6
Need Help?
Scope

1.1
This Standard applies to newly produced gas-fired outdoor infrared patio heaters (see Clause 3, Definitions) hereinafter referred to as heaters or appliances, constructed entirely of new, unused parts and materials.

Patio heaters are for use with:
a) natural gas; and
b) liquefied petroleum (propane) gases.

1.2
The heaters covered by this Standard are intended for installation in and heating of residential or nonresidential spaces (see Clause 3, Definitions).

1.3
Infrared patio heaters may be suspended overhead, angle mounted overhead, wall mounted, floor mounted, or for tabletop use.

1.4
Patio heaters intended for tabletop use shall be limited to input ratings of 15,000 Btu/hr (4 396 W) or less.

1.5
Infrared patio heaters may be for connection to:
a) a fixed fuel piping system operating at inlet gas pressures not exceeding 1/2 psi (3.5kPa); or
b) an integral self-contained liquefied petroleum (propane) gas supply system, provided the appliance incorporates mounting means for the attachment of a maximum of one cylinder limited to a maximum of 20 lb (9.1 kg) of fuel operating at regulated outlet:
i) pressure not exceeding 11 in wc (2.74 kPa); or
ii) pressures in excess of 11 in wc (2.74 kPa) but not greater than 5 psi (34.5 kPa).

1.6
Clause 2 contains a list of standards specifically referenced in this Standard and sources from which these reference standards may be obtained.

1.7
If a value for measurement as given in this Standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. This Standard contains SI (Metric) equivalents to the yard/pound quantities, the purpose being to allow the standard to be used in SI (Metric) units. (IEEE/ASTM-SI-10 is used as a guide in making metric conversion from yard/pound quantities.) If a value for a measurement and an equivalent value in other units, the first stated is to be regarded as the requirement. The given equivalent value may be approximate. If a value for a measurement and an equivalent value in other units, are both specified as a quoted marking requirement, the first stated unit, or both shall be provided.

1.8
In this Standard, "shall" is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition : 2nd
File Size : 1 file , 1.5 MB
ISBN(s) : 9781771396806
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 121
Product Code(s) : 2423259, 2423259
Published : 06/01/2014

History

CSA 2.37:20/ANSI Z83.26:20
Published Date: 11/01/2020
Gas-fired outdoor infrared patio heaters, Includes Errata (2021)
$135.6
CSA 2.37-2014/ANSI Z83.26-2014 (R2019)
Published Date: 06/01/2014
Gas-Fired Outdoor Infrared Patio Heaters
$135.6
CSA ANSI Z83.26-2007/CSA 2.37-2007 (R2012)
Published Date: 11/01/2007
Gas-Fired Outdoor Infrared Patio Heaters
$182.4

Related products

CSA ANSI Z21.76b-1997 (R2012)
Published Date: 01/01/1997
Addenda 2 to ANSI Z21.76-1994, Gas-Fired Unvented Catalytic Room Heaters for Use With Liquefied Petroleum (LP) Gases
$38.4
CSA ANSI Z21.40.1-1996 (R2022)/CGA 2.91-M96 (R2022)
Published Date: 11/01/2000
Gas-Fired, Heat Activated Air Conditioning and Heat Pump Appliances
$260.7
CSA ANSI Z21.11.2:19
Published Date: 07/01/2019
Gas-fired room heaters, volume II, unvented room heaters
$159.9

Best-Selling Products

AABC BASIC-PSYCHROMETRICS
Published Date:
TABpro Training Series Video - Basic Psychrometrics
$57.6
AABC BUNDLE
Published Date:
TABpro Training Series Video - Bundle (VAV, Duct Leakage & Psychrometrics)
$224.7
AABC DIRECTORY
Published Date: 01/01/2011
Directory
AABC DIRECTORY
Published Date: 01/01/2012
Directory
AABC DUCT LEAKAGE
Published Date:
TABpro Training Series Video - Duct Leakage and Pressure Decay Testing
$96
AABC KAHOE FIELD MANUAL
Published Date:
Kahoe Test and Balance Field Manual
$45.6