CSA 2.41-2014 / ANSI Z21.97-2014 PDF

CSA 2.41-2014 / ANSI Z21.97-2014 PDF

Name:
CSA 2.41-2014 / ANSI Z21.97-2014 PDF

Published Date:
03/01/2014

Status:
[ Withdrawn ]

Description:

Outdoor Decorative Gas Appliances

Publisher:
CSA Group

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
Need Help?

Preface

This is the second edition of ANSI Z21.97 - CSA 2.41, Outdoor decorative gas appliances. It supersedes the previous edition published in 2012.

Scope

1.1
This Standard applies to newly produced decorative gas appliances for outdoor installation (see Clause 3, Definitions), constructed entirely of new, unused parts and materials; hereinafter referred to as "appliance". Appliances submitted for examination under this Standard are classified as one of the following: portable, stationary, or built-in.

1.2
Appliances may be for:

a) connection to a fixed fuel piping system; or

b) connection to a self-contained liquefied petroleum (LP) gas supply system (see Clause 3, Definitions). Cylinder(s) for a self-contained system may be either remote to the appliance or integrally mounted on the appliance, and shall be designed for vapor withdrawal only.

    i) Appliances with input ratings less than 60,000 Btu/hr (17 584 W) shall be designed to accommodate a vertically mounted integral cylinder with a maximum size of 20 lb (9.1kg) of fuel.

    ii) Appliances with input ratings greater than or equal to 60,000 Btu/hr (17 584 W) may be designed to accommodate a vertically mounted integral cylinder with a maximum size of 30 lb (13.6 kg) of fuel.

    iii) Appliances with input ratings greater than or equal to 80,000 Btu/hr (23 446 W) may be designed for not more than two vertically mounted integral vapor withdrawal cylinders, each with a maximum size of 20 lb (9.1 kg) of fuel.

    iv) Portable appliances intended for table top use shall have input ratings limited to not more than 15,000 Btu/hr (4 396 W) and shall be designed to accommodate a vertically mounted cylinder with a maximum size of 16.4 oz (465 g) of fuel.

    v) Portable appliances with input ratings not greater than or equal to 25,000 Btu/hr (7 327 W) may be designed for the use of not more than two cylinders, each with a maximum size of 16.4 oz (465 g) of fuel.

    vi) Appliances designed for use with remote LP cylinders shall be limited to one cylinder of maximum 30 lb (13.6 kg) of fuel or two cylinders with maximum of 20 lb (9.1kg) of fuel each.
1.3
An appliance conforming to Clause 1.2b)ii), and that is capable of accepting either a 20 lb (9.1 kg) or a 30 lb (13.6 kg) LP-gas cylinder, shall have all applicable tests in Clause 4, Construction, and Clause 5, Performance, conducted with both size cylinders.

1.4
This Standard applies to appliances operating at inlet gas pressures not to exceed 1/2 psi (3.5 kPa) for connection to a fixed fuel piping system and for use with:

a) natural gas; and

b) liquefied petroleum gases.

1.5
The construction of an appliance for use with the above-mentioned gases is described in Clause 4, Construction.

The performance of an appliance for use with the above-mentioned gases is described in Clause 5, Performance.

1.6
This Standard also applies to appliances designed for connection to self-contained LP-gas supply systems:

a) operating at regulated outlet pressures not to exceed 11 in wc (2.74 kPa); or

b) operating at regulated outlet pressures in excess of 11 in wc (2.74 kPa) but not greater than 5 psi (34.5kPa).

1.7
Built-in appliances may be for:

a) connection to a fixed fuel piping system; or

b) connection to a remote self-contained liquefied petroleum gas supply system (see Clause 3, Definitions), provided the appliance is supplied with remote mounting and retention means for the attachment of a single cylinder with a maximum size in accordance with Clause 1.2b)i) or Clause 1.2b)ii) and instructions for installing the mounting and retention means within the built-in enclosure.

1.8
An appliance having integral mounting and retention means shall be designed so a spare 20 lb (9.1 kg) or 30 lb (13.6kg) LP-gas cylinder cannot be stored within any enclosure or under the firebox of the appliance.

1.9
An appliance shall not be thermostatically controlled.

1.10
If a value for measurement as given in this Standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification.

1.11
References to "psi" in this Standard are to be considered gauge pressure unless otherwise specified.

1.12
Clause 7 contains provisions that are unique to the United States.

1.13
Clause 8 contains provisions that are unique to Canada.

1.14
Clause 2, Reference publications, contains a list of standards specifically referenced in this Standard, and sources from which these reference standards may be obtained.

1.15
In this Standard, "shall" is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.


Edition : 2nd
ISBN(s) : 9781771393980
Number of Pages : 116
Published : 03/01/2014

History

CSA 2.41-2017/ANSI Z21.97-2017 (R2022)
Published Date: 12/01/2017
Outdoor Decorative Gas Appliances, Includes Errata No. 1 (2019) and Errata No. 2 (2021)
$130.5
CSA 2.41-2014 / ANSI Z21.97-2014
Published Date: 03/01/2014
Outdoor Decorative Gas Appliances
CSA 2.41 / ANSI Z21.97-2010
Published Date: 01/05/2010
American National Standard for Outdoor Decorative Gas Appliances
$215.4

Related products

CSA PLUS 1164 (1st ed. pub 2002)
Published Date: 01/01/2001
A Practical Handbook for Combining the Requirements of ISO 9001:2000 and ISO 14001:1996
$28.5
CSA C900.5:21
Published Date: 04/01/2021
Thermal energy meters - Part 5: Initial verification tests (Adopted CEN EN 1434-5:2015, edition 3:2015 consolidated with amendment 1:2019, with Canadian deviations)
$51.9
CSA Z245.20 Series:22
Published Date: 08/16/2022
Plant-applied external coatings for steel pipe, Includes Errata (2024)
$147
CSA C22.2 NO. 198.2:23
Published Date: 10/29/2023
Sealed Wire Connector Systems
$90.9

Best-Selling Products

NYBC NYBC
Published Date: 05/01/2002
New York Building Code
$19.8
NYBC NYBC
Published Date: 08/01/2010
Building Code of New York State
$33.3
NYBC NYBC
Published Date: 08/01/2007
New York Building Code
$30.6
NYBC NYBC
Published Date: 11/01/2019
2020 Building Code of New York State
$42.9
NYBC NYCBC
Published Date: 09/01/2022
2022 New York City Building Code
$53.1
NYBC NYCFC
Published Date: 10/01/2022
2022 New York City Fire Code
$37.2