CSA 2.7-M98/ANSI Z21.17-1998 (R2019) PDF

CSA 2.7-M98/ANSI Z21.17-1998 (R2019) PDF

Name:
CSA 2.7-M98/ANSI Z21.17-1998 (R2019) PDF

Published Date:
04/01/1999

Status:
Active

Description:

Domestic Gas Conversion Burners

Publisher:
CSA Group

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$215.7
Need Help?
Scope:

1.1.1
This Standard applies to newly produced domestic gas conversion burners constructed entirely of new, unused parts and materials and having input ratings at normal inlet test pressure of not more than 400,000 Btu per hour (117 228 W):
(a) For use with natural gas
(b) For use with manufactured gas
(c) For use with mixed gas
(d) For use with liquefied petroleum gases; and
(e) For use with LP gas-air mixtures.

The construction of conversion burners for use with the above-mentioned gases is covered under Part I.

The performance of conversion burners for use with the above-mentioned gases is covered under Part II.

1.1.2
If a value for measurement as given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification.

1.1.3
Exhibit A contains provisions that are unique to the United States.

1.1.4
Exhibit B contains provisions that are unique to Canada.

1.1.5
Exhibit C contains a list of standards specifically referenced in this standard, and sources from which these reference standards may be obtained.

1.1.6
All references to "psi" throughout this standard are to be considered gage pressures, unless otherwise specified.
Edition : 1st
File Size : 1 file , 2 MB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 106
Product Code(s) : 2413499, 2413499
Published : 04/01/1999

History


Related products

CSA CGA 3.4-1973 (R2020)
Published Date: 04/01/1973
Industrial and Commercial Gas-Fired Conversion Burners
$51.9
CSA C22.1:24
Published Date: 02/20/2024
Canadian Electrical Code, Part I (26th Edition), Safety Standard for Electrical Installations
$57
CSA ANSI Z21.11.2:19
Published Date: 07/01/2019
Gas-fired room heaters, volume II, unvented room heaters
$159.9
CSA 2.22:19/ANSI Z21.50:19
Published Date: 06/01/2019
Vented decorative gas appliances
$251.4

Best-Selling Products

SDI 106-99
Published Date: 01/01/1999
Recommended Standard Door Type Nomenclature
SDI 108-10
Published Date: 2010
Recommended Selection and Usage Guide for Standard Steel Doors
SDI 108
Published Date: 01/01/1990
Recommended Selection and Usage Guide for Standard Steel Doors
SDI 109
Published Date: 01/01/1988
Hardware for Standard Steel Doors and Frames
SDI 110-09
Published Date: 2009
Standard Steel Doors and Frames for Modular Masonry Construction
SDI 110
Published Date: 01/01/1984
Standard Steel Doors and Frames for Modular Masonry Construction