CSA B64.10-07/B64.10.1-07 PDF

CSA B64.10-07/B64.10.1-07 PDF

Name:
CSA B64.10-07/B64.10.1-07 PDF

Published Date:
07/01/2007

Status:
Active

Description:

Selection and Installation of Backflow Preventers/Maintenance and Field Testing of Backflow Preventers, Includes Update No. 1 (2008)

Publisher:
CSA Group

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$57
Need Help?
Preface

This volume contains the fifth edition of CSA B64.10, Selection and installation of backflow preventers, and the second edition of CSA B64.10.1, Maintenance and field testing of backflow preventers. CSA B64.10 supersedes the previous editions published in 2001 (under the title Manual for the Selection and Installation of Backflow Prevention Devices), 1994, 1988 (as part of the CAN/CSA-B64 Series), and 1981. CSA B64.10.1 supersedes the previous edition, published in 2001 under the title Manual for the Maintenance and Field Testing of Backflow Prevention Devices.

-----------------------------------------------------

B64.10-07

Selection and installation of backflow preventers

1 Scope

1.1 Application

This Standard specifies requirements for the selection and installation of backflow preventers. Additional information on how backflow due to back siphonage and back pressure occurs, and how to select and apply specific devices, is included in Annexes A, B, and C.

1.2 Exclusions

1.2.1

This Standard does not specify requirements for materials, construction, or performance tests of backflow preventers. Such requirements are specified in the CSA B64 Series, in ASME A112.18.1/CSA B125.1, and in CSA B125.3. See Table 1.

1.2.2

This Standard does not specify requirements for maintenance or field testing after the initial installation. Such requirements are specified in CSA B64.10.1.

1.3 Terminology

In CSA Standards, ""shall"" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; ""should"" is used to express a recommendation or that which is advised but not required; ""may"" is used to express an option or that which is permissible within the limits of the standard; and ""can"" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

1.4 Measurement This Standard is written in SI (metric) units. For conversion tables, see Annex D. Vacuum is expressed in pressure below ambient.

-----------------------------------------------------

B64.10.1-07

Maintenance and field testing of backflow preventers

1 Scope

1.1

This Standard specifies requirements for the maintenance and field testing of backflow preventers.

1.2

This Standard does not specify requirements for the selection and installation of backflow preventers. Such requirements are specified in CSA B64.10.

1.3

In CSA Standards, ""shall"" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; ""should"" is used to express a recommendation or that which is advised but not required; ""may"" is used to express an option or that which is permissible within the limits of the standard; and ""can"" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

1.4

This Standard is written in SI (metric) units. For conversion tables, see Annex D of CSA B64.10. Vacuum is expressed in pressure below ambient."


File Size : 1 file , 3.3 MB
ISBN(s) : 1554364272
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 154
Published : 07/01/2007

History

CSA B64.10:23/CSA B64.10.1:23
Published Date: 07/27/2023
Selection and installation of backflow preventers/Maintenance and field testing of backflow preventers, Includes Errata (2023)
$72
CSA B64.10-11/B64.10.1-11 (R2016)
Published Date: 11/01/2011
Selection and Installation of Backflow Preventers/Maintenance and Field Testing of Backflow Preventers
$55.2
CSA B64.10-07/B64.10.1-07
Published Date: 07/01/2007
Selection and Installation of Backflow Preventers/Maintenance and Field Testing of Backflow Preventers, Includes Update No. 1 (2008)
$57

Related products

CSA Z204-94 (R1999)
Published Date: 01/21/2000
Guideline for Managing Indoor Air Quality in Office Buildings
$20.4

Best-Selling Products

CAN/CSA-ISO/IEC ISP 10608-1-99 (R2003)
Published Date: 02/22/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 1: General Overview and Subnetwork- Independent Requirements (Adopted ISO/IEC 10608-1:1992, first edition)
$21.9
CAN/CSA-ISO/IEC ISP 10608-12-99 (2003)
Published Date: 02/18/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 12: MAC Sublayer and Physical Layer Dependent Requirements for a CSMA/CD LAN Subnetwork (Adopted ISO/IEC ISP 10608-12:1996)
$15.9
CAN/CSA-ISO/IEC ISP 10608-13-01
Published Date: 03/12/2001
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless-Mode Network Service - Part 13: MAC Sublayer and Physical Layer Dependent Requirements for a Token Ring LAN Subnetwork (Adopted ISO/IEC ISP 10608-13:1994, first edition, 1994-0
$15.9
CAN/CSA-ISO/IEC ISP 10608-14-99 (R2003)
Published Date: 02/19/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 14: MAC, PHY and PMD Sublayer Dependent and Station Management Requirements Over an FDDI LAN Subnetwork (Adopted ISO/IEC ISP 10608-14:1995)
$27
CAN/CSA-ISO/IEC ISP 10608-2-99 (R2003)
Published Date: 02/19/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 2: TA51 Profile Including Subnetwork Dependent Requirements for CSMA/CD Local Area Networks (LANs) (Adopted ISO/IEC ISP 10608-2:1992)
$15.9
CAN/CSA-ISO/IEC ISP 10608-4-99 (R2003)
Published Date: 02/18/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 4: Definition of Profile TA53, Operation Over a Token Ring LAN Subnetwork (Adopted ISO/IEC ISP 10608-4:1994, first edition)
$14.1