CSA C22.2 NO. 60601-1-10-09 (R2020) PDF

CSA C22.2 NO. 60601-1-10-09 (R2020) PDF

Name:
CSA C22.2 NO. 60601-1-10-09 (R2020) PDF

Published Date:
11/01/2009

Status:
Active

Description:

Medical electrical equipment - Part 1-10: General requirements for basic safety and essential performance - Collateral Standard: Requirements for the development of physiologic closed-loop controllers (Adopted 60601-1-10:2007, first edition,2007-11)

Publisher:
CSA Group

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$63
Need Help?
Preface:

This is the first edition of CAN/CSA-C22.2 No. 60601-1-10, Medical electrical equipment — Part 1-10: General requirements for basic safety and essential performance — Collateral Standard: Requirements for the development of physiologic closed-loop controllers, which is an adoption without modification of the identically titled IEC (International Electrotechnical Commission) Standard 60601-1-10 (first edition, 2007-11). It is one in a series of Standards issued by CSA under Part II of the Canadian Electrical Code.

1.1 Scope:

This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS.

This collateral standard specifies requirements for the development (analysis, design, VERIFICATION and VALIDATION) of a PHYSIOLOGIC CLOSED-LOOP CONTROLLER (PCLC) as part of a PHYSIOLOGIC CLOSED-LOOP CONTROL SYSTEM (PCLCS) in ME EQUIPMENT and ME SYSTEMS to control a PHYSIOLOGIC VARIABLE.

NOTE A PHYSIOLOGIC VARIABLE can be a body chemistry (e.g. electrolytes, blood glucose), a physical property (e.g. PATIENT temperature, electrophysiologic, hemodynamic), or a pharmaceutical concentration.

This collateral standard applies to various types of PCLC, e.g. linear and non-linear, adaptive, fuzzy, neural networks.

This collateral standard does not specify:
  • additional mechanical requirements; or
  • additional electrical requirements.
This collateral standard applies to a closed-loop controller (see Figure 1) that sets the CONTROLLER OUTPUT VARIABLE in order to adjust (i.e., change or maintain) the measured PHYSIOLOGIC VARIABLE by relating it to the REFERENCE VARIABLE.

A closed-loop controller that maintains a physical or chemical VARIABLE, using feedback that is not measured from a PATIENT, is outside the scope of this standard.

1.2 Object
The object of this collateral standard is to specify general requirements that are in addition to those of the general standard and to serve as the basis for particular standards.

1.3 Related standards

1.3.1 IEC 60601-1
For ME EQUIPMENT and ME SYSTEMS, this collateral standard complements IEC 60601-1. When referring to IEC 60601-1 or to this collateral standard, either individually or in combination, the following conventions are used:
  • "the general standard" designates IEC 60601-1 alone;
  • "this collateral standard" designates IEC 60601-1-10 alone;
  • "this standard" designates the combination of the general standard and this collateral standard.

Edition : 1st
File Size : 1 file , 1.5 MB
ISBN(s) : 9781554912629
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 102
Product Code(s) : 2419778, 2419778
Published : 11/01/2009

History


Related products


Best-Selling Products

ISO/TTA 1:1994
Published Date: 04/01/1994
Advanced technical ceramics - Unified classification system
$55.5
ISO/TTA 2:1997
Published Date: 04/01/1997
Tensile tests for discontinuously reinforced metal matrix composites at ambiant temperatures
$33.3
ISO/TTA 3:2001
Published Date: 09/01/2001
Polycrystalline materials - Determination of residual stresses by neutron diffraction
$55.5
ISO/TTA 4:2002
Published Date: 11/01/2002
Measurement of thermal conductivity of thin films on silicon substrates
$41.4
ISO/TTA 5:2007
Published Date: 10/01/2007
Code of practice for creep/fatigue testing of cracked components
$75