CSA C301.2-M1979 (R2003) PDF

CSA C301.2-M1979 (R2003) PDF

Name:
CSA C301.2-M1979 (R2003) PDF

Published Date:
05/30/2000

Status:
Active

Description:

Three-Phase Submersible Distribution Transformers, Type ONAN

Publisher:
CSA Group

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$9.6
Need Help?
1. Scope

1.1

This Standard covers the features of three-phase submersible transformers. For other details, reference shall be made to CSA Standard C2, Single-Phase and Three-Phase Distribution Transformers Types ONAN and LNAN, which is hereinafter referred to as CSA Standard C2.

Note: Included with this Standard is Appendix A, Recommendations for Corrosion Control of Submersible Transformer Installations, which covers handling and installation, cathodic protection, maintenance and records recommendations that the user should follow to ensure an acceptable service life.

1.2

The rated kV?A capacities at rated voltage shall be 75, 150, 225, 300, 500, 750, and 1000.

1.3

This Standard applies only to three-phase distribution transformer units intended for use in a ventilated vault or enclosure below grade level with all terminations and accessories cover mounted for operation from above grade. It does not apply to directly buried transformers in contact with the earth, to permanently submerged transformers, or to network type transformers.

1.4

The equipment covered by this Standard is primarily inte nded for operation by electric utilities on three-phase underground distribution systems having primary voltages as shown in Table 1.

1.5

When this equipment is intended for operation by other than an electric utility, it shall be the purchaser's responsibility to ensure that the unit meets the requirements of the appropriate electrical inspection authority.

1.6

The equipment covered by this Standard may have two HV bushings for each phase, designed for circuit loop feed within the transformer tank. High-voltage switching and fusing may be connected between these internal loop feed elements and the transformer high-voltage winding; they are not covered by this Standard and should be specified by the purchaser.
File Size : 1 file , 290 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 26
Published : 05/30/2000

History

CSA C301.2-06 (R2022)
Published Date: 02/28/2006
Three-Phase Submersible Distribution Transformers
$28.5
CSA C301.2-M1979 (R2003)
Published Date: 05/30/2000
Three-Phase Submersible Distribution Transformers, Type ONAN
$9.6

Related products

CSA B242:05 (R2021)
Published Date: 09/01/2005
Groove- and Shoulder-Type Mechanical Pipe Couplings
$54.3
CSA C22.2 NO. 60601-1-3:09 (R2019)
Published Date: 11/01/2009
Medical electrical equipment - Part 1-3: General requirements for basic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment (Adopted IEC 60601-1:2005, second edition, with Canadian deviations)
$69.3
CSA ANSI HGV 3.1:22
Published Date: 09/30/2022
Fuel system components for compressed hydrogen gas powered vehicles
$120
CSA PLUS 4011.1:19
Published Date: 11/01/2019
Technical Guide: Design and construction considerations for foundations in permafrost regions
$37.5

Best-Selling Products

ACCA 609
Published Date:
Refrigeration and Air Conditioning Technology
ACCA MANUAL J
Published Date: 01/01/2016
Residential Load Calculation
ACCA MANUAL N
Published Date: 01/01/2011
Commercial Load Calculation
Architectural Sheet Metal Inspection Guide
Published Date: 10/01/2004
$24.9