CSA C862-09 PDF

CSA C862-09 PDF

Name:
CSA C862-09 PDF

Published Date:
11/01/2009

Status:
Active

Description:

Performance of Incandescent Reflector Lamps

Publisher:
CSA Group

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$40.2
Need Help?
Preface

This is the fourth edition of CSA C862, Performance of incandescent reflector lamps. It supersedes the previous editions, published in 2001, 1997, and 1995.

Scope

1.1
This Standard describes testing procedures and states the performance requirements for general service incandescent and tungsten halogen reflector lamps.

1.2
This Standard includes performance requirements for
(a) wattage;
(b) lamp efficacy;
(c) rated luminous flux;
(d) centre beam intensity; and
(e) rated life.

1.3
This Standard applies to incandescent and tungsten halogen reflector lamps designed for general lighting use that have
(a) a rated wattage from 40 W up to and including 205 W;
(b) an operating capability between 110 and 130 V;
(c) an E26/24 single contact, or E26/50∗39 skirted, medium screw base; and
(d) a bulb diameter > 57 mm.

1.4
This Standard does not apply to any of the following:
(a) coloured lamps;
(b) lamps that
(i) are of rough (or vibration) service type and are specifically marked and marketed as rough (or vibration) service lamps;
(ii) have a lens containing at least 5% neodymium oxide;
(iii) have a coating or other containment system to retain glass fragments if the lamp is shattered and are specifically marked and marketed as impact-resistant lamps; or
(iv) contain a filter that suppresses yellow and green portions of the spectrum and are specifically marked and marketed for plant growth use;
(c) infrared heat lamps;
(d) lamps used in mines or in airfield, aircraft, automotive, marine, aquarium, terrarium, or vivarium applications;
(e) a bulb shape designated as BR as described in NEMA/ANSI C79.1 with
(i) a diameter of 95.25 mm (BR 30) and a rated power of . 50 W;
(ii) a diameter of 95.25 mm (BR 30) and a rated power of 65 W;
(iii) a diameter of 127 mm (BR 40) and a rated power of . 50 W; or
(iv) a diameter of 127 mm (BR 40) and a rated power of 65 W;
(f) a bulb shape designated as ER as described in NEMA/ANSI C79.1 with
(i) a diameter of 95.25 mm (ER 30) and a rated power of . 50 W;
(ii) a diameter of 127 mm (ER 40) and a rated power of . 50 W; or
(iii) a diameter of 127 mm (ER 40) and a rated power of 65 W;
(g) a bulb shape designated as R as described in NEMA/ANSI C79.1 with a diameter of 63.5 mm (R 20) and a rated power of . 45 W;
(h) bowl mirror lamps (e.g., silverbowl); or
(i) lamps for heat-sensitive applications (i.e., dichroic cool beam).

1.5
In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition : 4th
File Size : 1 file , 380 KB
ISBN(s) : 9781554913152
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 26
Product Code(s) : 2420314, 2420314
Published : 11/01/2009

History

CSA C862-09
Published Date: 11/01/2009
Performance of Incandescent Reflector Lamps
$40.2

Related products

CSA ANSI Z83.8A-1998/2.6A-M98
Published Date: 04/01/1998
Addenda 1 to ANSI Z83.8-1996/CGA 2.6-M96, Gas Unit Heaters and Gas-Fired Duct Furnaces
$23.7
CSA S16:24
Published Date: 04/09/2024
Design of steel structures
$75
CSA CSA/ANSI HGV 4.4:21
Published Date: 06/01/2021
Gaseous hydrogen - Fuelling stations - Valves
$83.7
CSA C745:20
Published Date: 06/01/2020
Energy efficiency of electric storage tank water heaters and heat pump water heaters, with Administrative Update (2020)
$24.3

Best-Selling Products

JOTP JOTP-001
Published Date: 01/08/2013
Allied Ammunition Safety and Suitability for Service Assessment Testing Publication - Guidance
$7.2
JOTP JOTP-010
Published Date: 01/08/2013
Safety and Suitability for Service Assessment Testing for Shoulder Launched Munitions
$18
JOTP JOTP-010A
Published Date: 11/07/2014
Safety and Suitability for Service Assessment Testing for Shoulder Launched Munitions
$18
JOTP JOTP-010B
Published Date: 05/09/2016
Safety and Suitability for Service Assessment Testing for Shoulder Launched Munitions
$18
JOTP JOTP-011
Published Date: 12/05/2014
Safety and Suitability for Service Assessment Testing for Surface and Underwater Launched Munitions
$18
JOTP JOTP-012
Published Date: 07/01/2013
Safety and Suitability for Service Assessment Testing for Aircraft Launched Munitions
$18