DANSK DS/EN 13384-2 PDF

DANSK DS/EN 13384-2 PDF

Name:
DANSK DS/EN 13384-2 PDF

Published Date:
04/20/2015

Status:
[ Revised ]

Description:

Chimneys – Thermal and fluid dynamic calculation methods – Part 2: Chimneys serving more than one heating appliance

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$33
Need Help?

This part of EN 13384 specifies methods for calculation of the thermal and fluid dynamic characteristics of chimneys serving more than one heating appliance. This part of EN 13384 covers both the cases, either a) where the chimney is connected with more than one connecting flue pipe from individual or several appliances in a multi-inlet arrangement; or b) where the chimney is connected with an individual connecting flue pipe connecting more than one appliance in a cascade arrangement. The case of multiple inlet cascade arrangement is covered by the case a). This part of EN 13384 deals with chimneys operating under negative pressure conditions (there can be positive pressure condition in the connecting flue pipe) and with chimneys operating under positive pressure conditions and is valid for chimneys serving heating appliances for liquid, gaseous and solid fuels. This part of EN 13384 does not apply to: - chimneys with different thermal resistance or different cross-section in the various chimney segments. This part does not apply to calculate energy gain; - chimneys with open fire places, e.g. open fire chimneys or chimney inlets which are normally intended to operate open to the room; - chimneys which serve different kinds of heating appliances regarding natural draught, fan assisted, forced draught or combustion engine. Fan assisted appliances with draught diverter between the fan and the chimney are considered as natural draught appliances; - chimneys with multiple inlets from more than 5 storeys. (This does not apply to balanced flue chimney.); - chimneys serving heating appliances with open air supply through ventilation openings or air ducts, which are not installed in the same air supply pressure region (e.g. same side of building). For positive pressure chimneys this part only applies if any heating appliance which is out of action can be positively isolated to prevent flue gas back flow.


Edition : 15
File Size : 1 file , 1.9 MB
Number of Pages : 76
Product Code(s) : DS-061, DS-061
Published : 04/20/2015

History

DANSK DS/EN 13384-2+A1
Published Date: 07/08/2019
Chimneys – Thermal and fluid dynamic calculation methods – Part 2: Chimneys serving more than one heating appliance
$33
DANSK DS/EN 13384-2
Published Date: 04/20/2015
Chimneys – Thermal and fluid dynamic calculation methods – Part 2: Chimneys serving more than one heating appliance
$33

Related products

DANSK DS/EN 60071-2
Published Date: 01/30/1997
Insulation co-ordination – Part 2: Application guide
$48.9
DANSK DS/ISO 7870-2
Published Date: 03/21/2023
Control charts – Part 2: Shewhart control charts
$33.6
DANSK DS/EN 50446
Published Date: 12/11/2006
Straight thermocouple assembly with metal or ceramic protection tube and accessories
$15.3
DANSK DS/ISO 11898-2
Published Date: 03/26/2024
Road vehicles – Controller area network (CAN) – Part 2: High-speed physical medium attachment (PMA) sublayer
$36.6

Best-Selling Products

CIMA AP-0802
Published Date: 01/01/2008
AERIAL PLATFORM SAFETY MANUAL
$1.8
CIMA ASP-0806
Published Date: 01/01/2008
Asphalt Paver Safety Manual
$1.2
CIMA AT03-01
Published Date: 01/01/2005
AGRICULTURAL TRACTOR SAFETY MANUAL
$1.8
CIMA BL02-08
Published Date: 01/01/2018
Backhoe Loader Safety Manual
$2.1
CIMA BL02-08
Published Date: 01/01/2011
BACKHOE LOADER SAFETY MANUAL
CIMA C-70-2
Published Date: 01/01/2014
Mobile Crane Safety Manual