The purpose of this European Sstandard is to specify:
_ the dimensional, hygiene, tightness, pressure performance, hydraulic, acoustic, mechanical and physico-chemical characteristics which inlet valves for flushing cisterns shall comply with;
_ the test methods for checking these characteristics;
_ marking and presentation.
This standard applies exclusively to the valve itself and it does not prejudge compliance with health regulations as the inlet valve is being fitted into the cistern.
This document does not cover valves intended to equip flushing cisterns with external overflow.
This standard applies to valves such as float valves limit operating at pressures up to NP 10 (whose operating range is from 0,.05 MPa to 1 MPa - 0,.5 bar to 10 bar) designed to supply cold water to flushing cisterns for use with WC pans, that are permanently connected to a potable water supply system.
The working range can be extended downwards (< 0,.05 MPa - 0,.5 bar) down to 0,.01 MPa (0,.1 bar), in which case the manufacturer's instructions shall indicate this possibility as well as the recommended working range.
Range which shall be covered
Optional range
This standard does not apply to valves used for other applications: pumping tanks, storage tanks, etc.
Table 1 - Working conditions for flushing cistern inlet valves
Operating limits Limit recommended for proper functioning
(dynamic pressure)
Minimum dynamic pressure P 3 0,.05 MPa (0,.5 bar) *a 0,.1 MPa £ P £ 0,.5 Mpa (1 bar £ P £ 5 bar)
Maximum static pressure P £ 1 MPa (10 bar)
*a At the manufacturer's request, the minimum pressure (opening-closing) can be lowered.
| Edition : | 04 |
| File Size : | 1 file , 340 KB |
| Number of Pages : | 23 |
| Product Code(s) : | DS-021, DS-021 |
| Published : | 11/17/2004 |