DANSK DS/EN 15502-2-1 PDF

DANSK DS/EN 15502-2-1 PDF

Name:
DANSK DS/EN 15502-2-1 PDF

Published Date:
09/28/2022

Status:
[ Active ]

Description:

Gas-fired central heating boilers – Part 2-1: Specific standard for type C appliances and type B2, B3 and B5 appliances of a nominal heat input not exceeding 1 000 kW

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$42.9
Need Help?

This document specifies the requirements and test methods, as well as the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as "boilers". This document is intended to be used in conjunction with EN 15502-1:2021. This document covers gas-fired central heating boilers from the types C1 up to C(11) and the types B2, B3 and B5: NOTE 1 – For further background information on appliance types see EN 1749:2020. a) that have a nominal heat input (on the basis of net calorific value) not exceeding 1 000 kW; b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021; c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation; d) where the maximum operating pressure in the water circuit does not exceed 6 bar; e) which can give rise to condensation under certain circumstances; f) which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler"; if no declaration is given the boiler is to be considered a "standard boiler"; g) which are intended to be installed inside a building or in a partially protected place; h) which are intended to produce also hot water either by the instantaneous or storage principle as a single unit; i) which are designed for either sealed water systems or for open water systems; j) which are either modular boilers, or non-modular boilers. k) which are from the types C(10) that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa, and C(11) that have condensing boiler modules that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa. NOTE 2 – This document provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard, the risk associated with this alternative construction needs to be assessed. An example of an assessment methodology, based upon risk assessment, is given in Clause 11. This document does not cover all the requirements for: aa) appliances above 1 000 kW; ab) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB of EN 15502-1:2021); ac) appliances using flue dampers; ad) appliances of the types B21, B31, B51, C21, C41, C51, C61, C71, C81, C(12) and C(13); ae) C7 appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW; af) appliances incorporating flexible plastic flue liners; ag) C(10) boilers: 1) without a gas-air ratio control, or 2) which are non-condensing appliances, or 3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min)); ah) C(11) boilers that have boiler modules: 1) without a gas-air ratio control, or 2) which are non-condensing appliances, or 3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min)); ai) appliances intended to be connected to a flue having mechanical extraction; aj) surface temperatures of external parts particular to children and elderly people; ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas; al) appliances equipped with an adaptive combustion control function (ACCF); am) boilers intended to be installed in areas accessible to elderly people and children.


Edition : 22#
File Size : 1 file , 4.5 MB
Number of Pages : 104
Product Code(s) : DS-101, DS-101
Published : 09/28/2022

History

DANSK DS/EN 15502-2-1
Published Date: 09/28/2022
Gas-fired central heating boilers – Part 2-1: Specific standard for type C appliances and type B2, B3 and B5 appliances of a nominal heat input not exceeding 1 000 kW
$42.9
DANSK DS/EN 15502-2-1+A1
Published Date: 12/20/2016
Gas-fired central heating boilers – Part 2-1: Specific standard for type C appliances and type B2, B3 and B5 appliances of a nominal heat input not exceeding 1 000 kW
$38.7

Related products

DANSK DS/EN 50676
Published Date: 01/03/2020
Electrical equipment used for detection and concentration measurement of refrigerant gases – Performance requirements and test methods
$18
DANSK DS/EN 60044-1
Published Date: 03/21/2000
Instrument transformers - Part 1: Current transformers
$63.9
DANSK DS/EN 61243-3
Published Date: 12/15/2014
Live working – Voltage detectors – Part 3: Two-pole low-voltage type
$35.7
DANSK DS/ISO/IEC 13568
Published Date: 12/05/2002
Information technology - Z formal specification notation - Syntax, type system and semantics
$50.4

Best-Selling Products

MEDDEV 13/93
Published Date:
Guidelines Relating to the Application of: The Council Directive 90/385/EEC on Active Implantable Medical Devices and The Council Directive 93/42/EEC on Medical Devices
MEDDEV 2.1/3
Published Date: 03/01/1998
Guidelines Relating to the Demarcation Between 90/385/EEC on Active Implatable Medical Devices, 93/42/EEC on Medical Devices,65/65/EEC Relating to Medicinal Products & Related Directives
MEDDEV 3/94
Published Date: 04/01/1994
Guidelines Relating to the Application of : The Council Directive 90/385/EEC on Active Implantable Medical Devices and The Council Directive 93/42/EEC on Medical Devices