DANSK DS/EN 300 386 V2.1.1 PDF

DANSK DS/EN 300 386 V2.1.1 PDF

Name:
DANSK DS/EN 300 386 V2.1.1 PDF

Published Date:
08/01/2016

Status:
[ Active ]

Description:

Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements; Harmonised Standard covering the essential requirements of the Directive 2014/30/EU

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$30.3
Need Help?

The present document covers the EMC requirements for non-radio equipment intended to be used within a public telecommunications network, which provides telecommunications between Network Termination Points (NTPs) (i.e. excluding terminal equipment beyond the NTPs). Examples of such equipment are: • Switching equipment. Such equipment includes: - local telephone exchanges; - remote switching concentrators; - international switches; - telex switches; - network packet switches; - base station controllers, radio network controllers; - network servers and gateways. • Non-radio transmission equipment and ancillary equipment. Such equipment includes: - multiplexers; - line equipment and repeaters, e.g. equipment for: 􀀀 Synchronous Digital Hierarchy (SDH); 􀀀 Plesiochronous Digital Hierarchy (PDH); 􀀀 Asynchronous Transfer Mode (ATM); such as: 􀀀 Digital Cross Connect systems; 􀀀 network terminations; 􀀀 transmission equipment used in the access network like xDSL. • Power supply equipment. Such equipment includes: - central power plant; - end of suite power supplies; - uninterruptible power supplies; - stabilized AC power supplies; and - other dedicated telecommunication network power supplies; but excludes equipment which is uniquely associated with or integrated in other equipment. • Supervisory equipment. Such equipment includes: - network management equipment; - operator access maintenance equipment; - traffic measurement systems; - line test units; - functional test units. NOTE: The function of supervision may either be performed by independent equipment or form part of other telecommunication network equipment. If the function of supervision forms part of a telecommunication network equipment, the performance may be evaluated simultaneously with other functions (such as switching and transmission) during EMC testing. • Data centre equipment which is intended to be used within telecommunication network infrastructure: - Storage. - Processor. - Server. The environmental classification locations used in the present document refers to ETSI TR 101 651 [i.22]. The requirements of the present document have been selected to ensure an adequate level of immunity for the apparatus covered by the scope of the present document. The levels do not, however, cover extreme cases which may occur at any location but with a low probability of occurrence. In special cases, situations may arise where the levels of disturbance may exceed the immunity test levels specified in the present document. In these instances, special mitigation measures may have to be employed. General purpose equipment, which is used as a part of a telecommunication network, may be covered by the scope of other standards. For such equipment, if those other standards fully cover the requirements of the present document, no further assessment is necessary. Equipment which also fall within the scope of CENELEC EN 50083-2 [3] may require additional testing on the relevant RF ports. See clause 9.2 and annex D. Equipment may provide different functions, i.e. switching equipment may also provide transmission functions and transmission equipment may provide storage capabilities etc. All available functions of the EUT are to be tested.


Edition : 16
File Size : 1 file , 870 KB
Number of Pages : 56
Product Code(s) : DS-051, DS-051
Published : 08/01/2016

History


Related products

DANSK DSF/EN 60730-2-5/PRA2 {FRAG 2}
Published Date:
Automatic electrical controls – Part 2-5: Particular requirements for automatic electrical burner control systems
$4.2
DANSK DS/EN 60335-2-28
Published Date: 10/24/2003
Household and similar electrical appliances – Safety – Part 2-28: Particular requirements for sewing machines
$31.5
DANSK DS/EN 17501
Published Date: 06/15/2022
Non-destructive testing – Thermographic testing – Active thermography with laser excitation
$19.2

Best-Selling Products

AEIC CG1-19
Published Date: 06/01/2019
Guide for Establishing the Maximum Operating Temperatures of Impregnated Paper and Laminated Paper Polypropylene Insulated Cable - 5th Edition
$15
AEIC CG14-19
Published Date: 10/24/2019
Guide for the Design of Transmission Vaults - 1st Edition
$21
AEIC CG3-21
Published Date: 02/01/2022
Guide for Installation of Pipe-Type Cable Systems - 3rd Edition
$15
AEIC CG4-97
Published Date: 01/01/1997
Guide for Installation of Extruded Dielectric Insulated Power Cable Systems Rated 69 kV Through 138 kV - 2nd Edition
$15
AEIC CG5-05
Published Date: 06/01/2005
Underground Extruded Power Cable Pulling Guide
AEIC CS2-23
Published Date: 02/01/2023
Specification for Impregnated Paper and Laminated Paper Polypropylene Insulated High Pressure Pipe Type Cable - 8th Edition
$36