EN 50264-2-1 specifies requirements for, and constructions and dimensions of, single core cables
of the following types and voltage ratings:
- 0,6/1 kV unscreened, unsheathed (1 mm² to 400 mm²);
- 1,8/3 kV unscreened, unsheathed (1,5 mm² to 400 mm²);
- 1,8/3 kV unscreened, sheathed (1,5 mm² to 400 mm²);
- 3,6/6 kV unscreened, sheathed (2,5 mm² to 400 mm²).
All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogenfree sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a
duration of 5 s.
Under fire conditions the cables exhibit special performance characteristics in respect of maximum
permissible flame propagation (flame spread) and maximum permissible emission of smoke and
toxic gases.
EN 50264-2-1 should be read in conjunction with Part 1 "General requirements".