DANSK DS/EN 50341-2-15 PDF

DANSK DS/EN 50341-2-15 PDF

Name:
DANSK DS/EN 50341-2-15 PDF

Published Date:
05/27/2019

Status:
[ Active ]

Description:

Overhead electrical lines exceeding AC 1 kV – Part 2-15: National Normative Aspects (NNAs) for the Netherlands (based on EN 50341-1:2012)

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$33
Need Help?
SAME AS BS EN 50341-1

NL.1 Application to existing overhead lines This NNA is applicable for new high-voltage overhead lines only, not for existing lines in the Netherlands. NOTE: If some planning/design or modification works on existing lines in the Netherlands has to be performed, the structural integrity shall be assessed based on the following generic building standards: − NEN 8700 “Assessment of existing structures in case of reconstruction and disapproval – Basic Rules” and − NEN 8701 “Assessment of existing structures in case of reconstruction and disapproval – Actions NEN 8700 and NEN 8701 shall be used in conjunction with EN 50341 part 1 and this NNA. NEN 8700 and NEN 8701 are based on NEN-EN 1990. EN 50341-1 “Overhead electrical lines exceeding 1 kV” is based on EN 1990. Where in NEN-EN 1990 and NEN-EN 50341 is referred to 'design' that term should be read in the context of the applying this standard to a review or assessment, by an analysis, as 'verification'. In case of construction re-design this must be understood as referring only to the part of the structure that is subject of the re-design. (ncpt) NL.2 Application to cables for telecommunication This NNA includes the requirements for application of plastic cables, with metal or without (ADSS) metal, for telecommunication, as well as for conductor/earthwire (groundwire) systems (e.g. wraparound,....). (ncpt) NL.3 Application to mounting of telecommunication equipment This NNA is applicable for fixing of structural elements for telecommunication (e.g. dishes), if mounted on power line supports (towers), especially regarding the wind forces and ice loads on such fixed elements. (ncpt) NL.4 Applicability This NNA is applicable to overhead electrical lines exceeding 45 kV (A.C.). To overhead electrical lines exceeding 1 kV (A.C.) but lower than 45 kV (A.C.) Part 1 is applicable without special national conditions (snc) or national complements (ncpt).


Edition : 19
File Size : 1 file , 5.6 MB
Number of Pages : 65
Product Code(s) : DS-061, DS-061
Published : 05/27/2019

History


Related products

DANSK DS/ISO/TR 17987-5
Published Date: 11/08/2016
Road vehicles – Local Interconnect Network (LIN) – Part 5: Application programmers interface (API)
$30
DANSK DS/ISO 20813
Published Date: 05/13/2019
Molecular biomarker analysis – Methods of analysis for the detection and identification of animal species in foods and food products (nucleic acid-based methods) – General requirements and definitions
$24.9
DANSK DS/EN ISO 717-1
Published Date: 12/21/2020
Acoustics – Rating of sound insulation in buildings and of building elements – Part 1: Airborne sound insulation
$23.4
DANSK DS/EN 897
Published Date: 02/13/2013
Chemicals used for treatment of water intended for human consumption - Sodium carbonate
$19.2

Best-Selling Products

RETA -- Industrial Safety and Health
Published Date: 2001
$42.6
RETA -- Troubleshooting Skills
Published Date: 2001
$37.8