DANSK DS/EN 60534-8-2 PDF

DANSK DS/EN 60534-8-2 PDF

Name:
DANSK DS/EN 60534-8-2 PDF

Published Date:
02/03/2012

Status:
[ Active ]

Description:

Industrial-process control valves - Part 8-2: Noise considerations - Laboratory measurement of noise generated by hydrodynamic flow through control valves

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$19.2
Need Help?
SAME AS IEC 60534-8-2

This part of IEC 60534-8 includes the method for measuring the sound pressure level due to liquid flow through a control valve and the method for determining the characteristic increase of noise due to the onset of cavitation. It also defines the equipment, methods and procedures for the laboratory measurement of the airborne sound needed to determine these characteristics. Two methods are provided for testing the noise generating characteristics of control valves. The first is a uniform method of measuring the radiated noise from the valve and the associated test piping including fixed flow restrictions through which the test fluid (water) is passing (see Note 1). The noise criteria are expressed by determining the sound pressure level of the valve under consideration. The second is a procedure for measuring the sound pressure levels within pipe systems upstream and downstream of the valve under fixed operating conditions. Since inaccuracies due to the pipe transmission are eliminated, this method shall be preferred for evaluation of the acoustical characteristic of valves. The noise characteristics to be determined are useful: a) to determine acoustical characteristics of valves and valve assemblies and the characteristic pressure ratio factor xFz of a control valve; b) to predict valve noise for given process conditions; c) to compare the performance of different valves and various measuring results; d) to plan measures for increasing service life and noise abatement; e) to determine possible adverse effects on ultra-sonic flow meter measurements; f) to enable proper sizing of sound absorbers. NOTE 1 Test fluids other than water or valves without downstream piping are not within the scope of this section of IEC 60534-8. NOTE 2 The factor xFz is used in a noise prediction method which is covered in IEC 60534-8-4.


Edition : 12
File Size : 1 file , 1.1 MB
Number of Pages : 30
Product Code(s) : DS-026, DS-026
Published : 02/03/2012

History


Related products

DANSK DS/EN ISO 8847
Published Date: 08/02/2021
Small craft – Steering gear – Cable over pulley systems (ISO 8847:2021)
$23.4
DANSK DS/ISO 10302-1
Published Date: 02/06/2024
Acoustics – Measurement of airborne noise emitted and structure-borne vibration induced by small air-moving devices – Part 1: Airborne noise measurement
$30
DANSK DS/EN 60512-16-13
Published Date: 09/26/2008
Connectors for electronic equipment - Tests and measurements - Part 16-13: Mechanical tests on contacts and terminations - Test 16m: Un-wrapping, solderless wrapped connections
$11.4
DANSK DS/EN 60061-1/A22
Published Date: 09/10/1999
Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps
$8.4