DANSK DS/EN 60976 PDF

DANSK DS/EN 60976 PDF

Name:
DANSK DS/EN 60976 PDF

Published Date:
02/01/2008

Status:
[ Active ]

Description:

Medical electrical equipment - Medical electron accelerators - Functional performance characteristics

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$38.7
Need Help?

This International Standard applies to medical ELECTRON ACCELERATORS when used, for
therapy purposes, in human medical practice.
This standard applies to medical ELECTRON ACCELERATORS which deliver a RADIATION BEAM of either X-RADIATION or ELECTRON RADIATION with NOMINAL ENERGIES in the range 1 MeV to 50 MeV at maximum ABSORBED DOSE RATES between 0,001 Gy s-1 and 1 Gy s-1 at 1 m from the RADIATION SOURCE and at NORMAL TREATMENT DISTANCES between 50 cm and 200 cm from the RADIATION SOURCE.
The present standard describes measurements and test procedures to be performed by the
MANUFACTURER at the design and construction stage of a medical ELECTRON ACCELERATOR but does not specify ACCEPTANCE TESTS to be performed after installation at the purchaser's site.
The accompanying report, IEC 60977, however, does suggest that many of the test procedures are appropriate for ACCEPTANCE TESTS.
The measurement conditions described in the present standard differ from those previously in use. This applies particularly to the PHANTOM position for measurements and the measurement of distances from the ISOCENTRE. These new conditions should be substituted for and not be added to previous methods.
This standard specifies test procedures for the determination and disclosure of functional performance characteristics, knowledge of which is deemed necessary for proper application and use of a medical ELECTRON ACCELERATOR and which are to be declared in the ACCOMPANYING DOCUMENTS together with the greatest deviation or variation to be expected under specific conditions in NORMAL USE. A format for presentation of functional performance values is given in Annex A.
It is recognized that inaccuracies in the test methods must be allowed for when assessing performance. However, it was not felt to be advisable to combine the errors into an overall performance tolerance but to keep them separate in the expectation that more accurate test methods will be evolved.
It is not intended that this standard should in any way inhibit the future development of new designs of equipment which may have operating modes and parameters different from those described herein, provided that such equipment achieves equivalent levels of performance for the TREATMENT of PATIENTS.
Except where otherwise stated this standard assumes that the medical ELECTRON ACCELERATORS have an ISOCENTRIC GANTRY. Where the equipment is non-isocentric, the
description of performance and test methods may need to be suitably adapted.
NOTE A statement of compliance with this standard does not necessarily imply that these tests will be or have been applied as TYPE TESTS or as individual tests.


Edition : 08
File Size : 1 file , 1.7 MB
Number of Pages : 106
Product Code(s) : DS-101, DS-101
Published : 02/01/2008

History


Related products

DANSK DS/EN 60839-11-32
Published Date: 03/21/2017
Alarm and electronic security systems – Part 11-32: Electronic access control systems – Access control monitoring based on Web services
$33
DANSK DS/EN 1300
Published Date: 10/03/2023
Secure storage units – Classification for high security locks according to their resistance to unauthorized opening
$30.3
DANSK DS/ISO 500-3
Published Date: 03/28/2014
Agricultural tractors - Rear-mounted power take-off types 1, 2, 3 and 4 - Main PTO dimensions and spline dimensions, location of PTO
$21.3
DANSK DS/CWA 17027-119
Published Date: 09/01/2016
Business Interoperability Interfaces for Public Procurement in Europe – E-Tendering – Part 119: Profile BII54 Tendering
$21.3

Best-Selling Products

OPEI 60335-2-107-2020
Published Date: 01/31/2020
Household and similar electrical appliances - Safety - Part 2-107: Particular requirements for robotic battery powered electrical lawnmowers (Amendment 1 Included)
$54
OPEI B175.6-2018
Published Date: 10/03/2018
Internal Combustion Engine-Powered Hand-Held Hedge Trimmers - Safety and Environmental Requirements
$54
OPEI B175.7-2019
Published Date: 08/26/2019
Outdoor Power Equipment - Internal Combustion Engine-Powered Hand-Held Pole Mounted Pruners - Safety and Environmental Requirements
$54
OPEI B71.1-2017
Published Date: 04/06/2017
Outdoor Power Equipment - Walk-Behind Mowers and Ride-On Machines with Mowers - Safety Specifications
$54
OPEI B71.10-2008
Published Date: 01/01/2008
Small Off-Road Ground-Supported Outdoor Power Equipment Gasoline Fuel System Test Procedures
$9
OPEI B71.10-2018
Published Date: 11/12/2018
Small Off-Road Ground-Supported Outdoor Power Equipment Gasoline Fuel System Test Procedures
$54