DANSK DS/EN 61557-15 PDF

DANSK DS/EN 61557-15 PDF

Name:
DANSK DS/EN 61557-15 PDF

Published Date:
07/23/2014

Status:
[ Active ]

Description:

Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. – Equipment for testing, measuring or monitoring of protective measures – Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$35.7
Need Help?
SAME AS IEC 61557-15

IEC 61557-15:2014 specifies requirements related to functional safety and is based on the IEC 61508 standard series for the realization of Insulation Monitoring Devices (IMD) as specified in IEC 61557-8 and for Insulation Fault Location Systems (IFLS) according to IEC 61557-9, according to phase 10 of the IEC 61508-1 lifecycle. These devices provide safety related functions for IT systems. This part of IEC 61557 is – concerned only with functional safety requirements intended to reduce the functional risk during the use of IMDs and IFLSs; – restricted to risks arising directly from the device itself or from several IMDs or IFLSs working together in a system; and – intended to define the basic safety functions provided by the devices. This part of IEC 61557 does not – deal with electrical safety according to IEC 61010-1 and the requirements of IEC 61557-8 and IEC 61557-9; – cover the hazard and risk analysis of a particular use of the IMD or IFLS; – identify all the safety functions for the application in which the IMD or IFLS is used; and – cover the IMD or IFLS manufacturing process. This part of IEC 61557 is to be used in conjunction with Part 8 and Part 9. Functional safety requirements depend on the application and should be considered as part of the overall risk assessment of the specific application. The supplier of IMDs and IFLSs is not responsible for the application. The application designer is responsible for the risk assessment and for specifying the overall functional safety requirements of the complete IT system and he should select the functional safety level (SIL) of the IMD and/or IFLS when their safety function is part of the functional safety assessment in the IT system.


Edition : 14
File Size : 1 file , 1.7 MB
Number of Pages : 81
Product Code(s) : DS-081, DS-081
Published : 07/23/2014

History


Related products

DANSK DS/ISO 7010
Published Date: 03/31/2020
Graphical symbols – Safety colours and safety signs – Registered safety signs
$57.3
DANSK DS/EN IEC 62677-2
Published Date: 02/05/2018
Heat shrinkable low and medium voltage moulded shapes – Part 2 Methods of test
$22.5
DANSK DS/EN ISO 4938
Published Date: 03/15/2016
Steel and iron - Determination of nickel content - Gravimetric or titrimetric method
$19.2

Best-Selling Products

864 none
Published Date: 01/01/1996
Guidelines for Canadian Drinking Water Quality - Sixth Edition
$7.2