DANSK DS/EN 62439-5 PDF

DANSK DS/EN 62439-5 PDF

Name:
DANSK DS/EN 62439-5 PDF

Published Date:
05/19/2010

Status:
[ Withdrawn ]

Description:

Industrial communication networks – High availability automation networks – Part 5: Beacon Redundancy Protocol (BRP)

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$27
Need Help?
W/D S/S BY DS/EN 62439-1 * SAME AS IEC 62439-5

IEC 62439-5:2010(E) is applicable to high-availability automation networks based on the ISO/IEC 8802-3 (IEEE 802.3) (Ethernet) technology. It specifies a redundancy protocol that is based on the duplication of the network, the redundancy protocol being executed within the end nodes, as opposed to a redundancy protocol built in the switches. Fast error detection is provided by two beacon nodes, the switchover decision is taken in every node individually. The cross-network connection capability enables single attached end nodes to be connected on either of the two networks. It cancels and replaces IEC 62439 published in 2008 and constitutes a technical revision. It includes the following significant technical changes with respect to IEC 62439 (2008): – adding a calculation method for RSTP (rapid spanning tree protocol, IEEE 802.1Q), – adding two new redundancy protocols: HSR (High-availability Seamless Redundancy) and DRP (Distributed Redundancy Protocol), – moving former Clauses 1 to 4 (introduction, definitions, general aspects) and the Annexes (taxonomy, availability calculation) to IEC 62439-1, which serves now as a base for the other documents, – moving Clause 5 (MRP) to IEC 62439-2 with minor editorial changes, – moving Clause 6 (PRP) was to IEC 62439-3 with minor editorial changes, – moving Clause 7 (CRP) was to IEC 62439-4 with minor editorial changes, and – moving Clause 8 (BRP) was to IEC 62439-5 with minor editorial changes, – adding a method to calculate the maximum recovery time of RSTP in a restricted configuration (ring) to IEC 62439-1 as Clause 8, – adding specifications of the HSR (High-availability Seamless Redundancy) protocol, which shares the principles of PRP to IEC 62439-3 as Clause 5, and – introducing the DRP protocol as IEC 62439-6.


Edition : 10
File Size : 1 file , 1.1 MB
Number of Pages : 50
Product Code(s) : DS-041, DS-041
Published : 05/19/2010

History


Related products

DANSK DS/CEN ISO/TS 14827-4
Published Date: 10/19/2022
Intelligent transport systems – Data interfaces between centres for transport information and control systems – Part 4: Data interfaces between centres for Intelligent transport systems (ITS) using XML (Profile B) (ISO/TS 14827-4:2022)
$19.2
DANSK DS/EN 61262-6
Published Date: 01/30/2013
Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 6: Determination of the contrast ratio and veiling glare index
$22.5
DANSK DS/EN 60068-2-13
Published Date: 10/31/2001
Environmental testing – Part 2: Tests – Test M: Low air pressure
$13.2
DANSK DSF/FPREN ISO 12402-7
Published Date:
Personal flotation devices – Part 7: Materials and components – Safety requirements and test methods (ISO/FDIS 12402-7:2019)
$20.7

Best-Selling Products

PIP ARC01015
Published Date: 06/01/2002
Architectural and Building Utilities Design Criteria
$55.5
PIP ARC01015
Published Date: 02/01/2009
Architectural and Building Utilities Design Criteria [Complete Revision]
$57
PIP ARC01015
Published Date: 12/01/2014
Architectural and Building Utilities Design Criteria [Complete Revision]
$55.5
PIP ARC01016-EEDS
Published Date: 02/01/2009
Electronic Entry Data Sheet for Building
$15
PIP ARC01016-EEDS
Published Date: 12/01/2014
Electronic Entry Data Sheet for Building [Complete Revision]
$15
PIP ARC01016
Published Date: 08/01/2002
Building Data Sheet
$15