Name:
DANSK DS/EN ISO 13736 PDF
Published Date:
06/10/2013
Status:
[ Revised ]
Publisher:
Dansk Standard
This International Standard specifies a method for the determination of the manual and automated closed-cup flash point of combustible liquids having flash points between –30,0 °C and at least 75,0 °C . However, the precision given for this method is only valid for flash points in the range −8,5 °C to 75,0 °C. This International Standard is not applicable to water-borne paints. NOTE 1 – Water-borne paints can be tested using ISO 3679[3]. NOTE 2 – See 9.1 for the importance of this test in avoiding loss of volatile materials. NOTE 3 – Liquids containing halogenated compounds can give anomalous results. NOTE 4 – The thermometer specified for the manual apparatus limits the upper test temperature to 70,0 °C.
| Edition : | 13 |
| File Size : | 1 file , 1.2 MB |
| Number of Pages : | 38 |
| Product Code(s) : | DS-036, DS-036 |
| Published : | 06/10/2013 |