DANSK DS/ETSI EN 303 347-3 V2.1.1 PDF

DANSK DS/ETSI EN 303 347-3 V2.1.1 PDF

Name:
DANSK DS/ETSI EN 303 347-3 V2.1.1 PDF

Published Date:
06/08/2021

Status:
[ Active ]

Description:

Meteorological Radars; Harmonised Standard for access to radio spectrum; Part 3: Meteorological Radar Sensor operating in the frequency band 9 300 MHz to 9 500 MHz (X band)

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$27
Need Help?
DS/ETSI EN 303 347-3 V2.1.1

The present document specifies technical characteristics and methods of measurements for X-band meteorological radar systems intended for the surveillance and classification of hydrometeors with the following characteristics: • Operating in the following frequency range: - 9 300 MHz to 9 500 MHz • Utilizing unmodulated pulses or phase/frequency modulated pulses also known as pulse compression. • The maximum output power (PEP) is not greater than 250 kW (i.e. 84 dBm). • The transceiver antenna connection and its feeding RF line are using a hollow metallic rectangular or elliptic waveguide. • The antenna is rotating and can be changed in elevation. • The antenna feed is waveguide based and the antenna is passive. • The orientation of the transmitted field from the antenna can be vertical or horizontal orientated or it can be both simultaneously. • At the transceiver output a RF circulator is used. NOTE 1: Since transceiver and antenna are based on hollow metallic rectangular waveguide the frequency range for measurements that needs to be addressed covers 6 556 MHz to 26 GHz. The lower limit of this frequency range is obtained as the cut-off frequency of the generally used WR90/WG16 waveguide according to IEC 60153-2 [i.2]. The upper limit corresponds to the upper limit stated in ERC/Recommendation 74-01 [1], Table 1. NOTE 2: Since at the transceiver output a RF circulator is used, it is assumed that the transceiver characteristics remain independent from the antenna. NOTE 3: Meteorological radar systems covered by the present document are expected to use the band 9 300 MHz to 9 500 MHz. According to provision 5.475B of the ITU Radio Regulations [4], ground-based radars used for meteorological purposes in the band 9 300 MHz to 9 500 MHz have priority over other radiolocation uses. NOTE 4: Further technical and operational characteristics of meteorological radar systems can be found in Recommendation ITU-R M.1849-1 [i.3]. NOTE 5: The relationship between the present document and essential requirements of article 3.2 of Directive 2014/53/EU [i.1] is given in Annex A.


Edition : 21
File Size : 1 file , 1.7 MB
Number of Pages : 41
Product Code(s) : DS-041, DS-041
Published : 06/08/2021

History

DANSK DSF/ETSI EN 303 347-3 V1.1.4 (2020-12)
Published Date:
Meteorological Radars; Harmonised Standard for access to radio spectrum; Part 3: Meteorological Radar Sensor operating in the frequency band 9 300 MHz to 9 500 MHz (X band)
$14.7
DANSK DSF/ETSI EN 303 347-3 V1.1.0 (2019-04)
Published Date:
Meteorological Radars; Harmonised Standard for access to radio spectrum; Part 3: X band Meteorological Radar Sensor operating in the frequency band 9 300 MHz to 9 500 MHz
$14.7
DANSK DS/ETSI EN 303 347-3 V2.1.1
Published Date: 06/08/2021
Meteorological Radars; Harmonised Standard for access to radio spectrum; Part 3: Meteorological Radar Sensor operating in the frequency band 9 300 MHz to 9 500 MHz (X band)
$27

Related products

DANSK DS/EN 301 466 V1.2.1
Published Date: 07/07/2016
Technical characteristics and methods of measurement for two-way VHF radiotelephone apparatus for fixed installation in survival craft
$27
DANSK DS/EN 60601-3-1
Published Date: 04/01/1998
Medical electrical equipment - Part 3-1: Essential performance requirements for transcutaneous oxygen and carbon dioxide partial pressure monitoring equipment
$23.4
DANSK DS/ISO 24516-4
Published Date: 04/29/2019
Guidelines for the management of assets of water supply and wastewater systems – Part 4: Wastewater treatment plants, sludge treatment facilities, pumping stations, retention and detention facilities
$36.6
DANSK DS/ISO 52016-3
Published Date: 10/02/2023
Energy performance of buildings – Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads – Part 3: Calculation procedures regarding adaptive building envelope elements
$36.6

Best-Selling Products