DANSK DS/IEC TS 62749 PDF

DANSK DS/IEC TS 62749 PDF

Name:
DANSK DS/IEC TS 62749 PDF

Published Date:
04/23/2015

Status:
[ Revised ]

Description:

Assessment of power quality – Characteristics of electricity supplied by public networks

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$30
Need Help?

This Technical Specification specifies the expected characteristics of electricity at the SUPPLY TERMINALS of public low, medium and high voltage, 50 or 60Hz, networks. NOTE – 1 – The boundaries between the various voltage levels may be different for different countries. In the context of this TS, the following terms for system voltage are used: λlt;br /λgt;• low voltage (LV) refers to UN ≤ 1 kV; λlt;br /λgt;• medium voltage (MV) refers to 1 kV < UN ≤ 35 kV; λlt;br /λgt;• high voltage (HV) refers to 35 kV < UN ≤ 230 kV; NOTE – 2 – Because of existing network structures, in some countries, the boundary between medium and high voltage can be different. Most of the recommendations for power quality at the SUPPLY TERMINALS are expressed as POWER QUALITY INDICES that describe the manner in which the characteristics of electricity vary. Such variations may appear random in time, with reference to any specific supply terminal, and random in location, with reference to any given instant of time. As such, the POWER QUALITY INDICES are based on the occurrence of the applicable electromagnetic phenomena: - continuous phenomena, i.e. deviations from the nominal value that occur continuously over time. Such phenomena occur mainly due to load pattern, changes of load, non195 linear loads or distributed generation, and - discontinuous phenomena or events, i.e. sudden and significant deviations from normal or desired wave shape which typically occur due to unpredictable events (e.g. faults) or external causes (e.g. weather conditions). The power quality indices and the recommended values are intended to be used as technical reference for regulatory purposes (e.g. in NETWORK CODES) or for contracts between network operator and network user (e.g. part of a CONNECTION AGREEMENT). Power quality requirements combine the obligations of NETWORK OPERATORS with the requirements of equipment or installations on the electromagnetic environment. It is worthwhile noting however, that the requirements of equipment or installations on the electromagnetic environment also include emission aspects that are addressed in other IEC standards (see chapter 2 and annex F). NOTE – 1 – Network operators are in charge of developing and operating the electricity supply system taking into account at the same time: • provision of adequate conditions for equipment, installations or other networks connected to their network; • avoidance of unnecessary costs. NOTE – 2 – In many countries, requirements concerning the essential characteristics of electricity at supply terminals of public networks are set, or controlled, by National Regulatory Authorities. In some cases, additional requirements or differences in requirements can be agreed by terms of a contract (usually a CONNECTION AGREEMENT) between an individual NETWORK USER and the network operator. Such a contract is most likely to arise for network users with relatively large electricity demand, supplied from the MV or HV network, or having power quality sensitive load. It may also arise in sparsely populated or difficult terrain, such as mountain regions, where distribution costs are high. In such an area a network user may be willing to accept a connection, at lower cost, which does not entirely comply with the power quality standards. NOTE – The quality indices and the recommended values appropriately cover the vast majority of locations under acceptable economic conditions, despite the differences in situations, provided that: • for mass-market products, emission requirements in standards such as IEC 61000-3-2, 3-3, 3-11and/or 3-12 are regularly and appropriately updated to take into account the development of markets and changes in technologies; • for large installations, emission levels are effectively controlled, e.g. through connection agreement; (Annex E lists some methods to improve power quality.) • network operators make use of appropriate methodologies and engineering practices, e.g. based on PLANNING LEVELS and IEC 61000-3-6, 3-7, 3-13 and/or 3-14. This Technical Specification applies to the phenomena listed in Table 1. Table 1: Classification of electromagnetic phenomena addressed by power quality


Edition : 15
File Size : 1 file , 1.8 MB
Number of Pages : 45
Product Code(s) : DS-041, DS-041
Published : 04/23/2015

History

DANSK DSF/IEC TS 62749 ED2
Published Date:
IEC TS 62749 ED2: Assessment of power quality – Characteristics of electricity supplied by public networks
$16.2
DANSK DS/IEC TS 62749
Published Date: 02/17/2020
Assessment of power quality – Characteristics of electricity supplied by public networks
$36.6
DANSK DS/IEC TS 62749
Published Date: 04/23/2015
Assessment of power quality – Characteristics of electricity supplied by public networks
$30

Related products

DANSK DS/EN IEC 62680-1-5
Published Date: 11/28/2019
Universal serial bus interfaces for data and power – Part 1-5: Common components – USB Audio 3.0 device class definition
$44.1
DANSK DS/EN 2591-303
Published Date: 02/12/1998
Aerospace series - Elements of electrical and optical connection - Test methods - Part 303: Cold/low pressure and damp heat
$11.4
DANSK DS/EN 60384-9
Published Date: 06/01/2015
Fixed capacitors for use in electronic equipment - Part 9: Sectional specification: Fixed capacitors of ceramic dielectric, Class 2
$23.4
DANSK DS/EN ISO 11615
Published Date: 12/13/2017
Health informatics – Identification of medicinal products – Data elements and structures for the unique identification and exchange of regulated medicinal product information (ISO 11615:2017)
$35.7

Best-Selling Products

ICAO 10000
Published Date: 2014
Manual on Flight Data Analysis Programmes (FDAP)
ICAO 10000
Published Date: 01/01/2014
Manual on Flight Data Analysis Programmes (FDAP)
ICAO 10000
Published Date: 01/01/2021
Manual on Flight Data Analysis Programmes (FDAP)
ICAO 10000
Published Date: 01/01/2021
Руководство по программам анализа полетных данных (ПАПД)
ICAO 10000
Published Date: 01/01/2021
Manuel sur les programmes d’analyse des données de vol (FDAP)
ICAO 10000
Published Date: 01/01/2014
Manual on Flight Data Analysis Programmes (FDAP)