Name:
DANSK DS/ISO 10396 PDF
Published Date:
03/13/2007
Status:
[ Active ]
Publisher:
Dansk Standard
1.1 General
This International Standard specifies procedures and equipment that will permit, within certain limits, representative sampling for the automated determination of gas concentrations of effluent gas streams. The application is limited to the determination of oxygen (O2), carbon dioxide (CO2), carbon monoxide (CO), sulphur dioxide (SO2), nitrogen monoxide (NO) and nitrogen dioxide (NO2), or the sum of NO and NO2 as nitrogen oxides. Although they are only mentioned briefly in this International Standard, detailed velocity measurements (ISO 10780) are required when the mass flow rates of gases has to be determined.
1.2 Limitations
It is recognized that there are some combustion processes and situations that may limit the applicability of this International Standard. Where such conditions exist, caution and competent technical judgment are required, especially when dealing with any of the following:
a) corrosive or highly reactive components such as ammonia, hydrogen chloride and sulphuric acid ;
b) high vacuum, high pressure or high temperature gas streams;
c) wet flue gases;
d) fluctuations in velocity, temperature or concentration due to uncontrollable variation in the process;
e) gas stratification due to the non-mixing of gas streams;
f) measurements made using environmental control devices;
g) relatively low levels of gas concentrations.
| Edition : | 07 |
| File Size : | 1 file , 730 KB |
| Number of Pages : | 34 |
| Product Code(s) : | DS-031, DS-031 |
| Published : | 03/13/2007 |