DANSK DS/ISO 22017 PDF

DANSK DS/ISO 22017 PDF

Name:
DANSK DS/ISO 22017 PDF

Published Date:
08/31/2020

Status:
[ Active ]

Description:

Water quality – Guidance for rapid radioactivity measurements in nuclear or radiological emergency situation

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$21.3
Need Help?

This document provides guidelines for testing laboratories wanting to use rapid test methods on water samples that may be contaminated following a nuclear or radiological emergency incident. In an emergency situation, consideration should be given to: — taking into account the specific context for the tests to be performed, e.g. a potentially high level of contamination; — using or adjusting, when possible, radioactivity test methods implemented during routine situations to obtain a result rapidly or, for tests not performed routinely, applying specific rapid test methods previously validated by the laboratory, e.g. for 89Sr determination; — preparing the test laboratory to measure a large number of potentially contaminated samples. The aim of this document is to ensure decision makers have reliable results needed to take actions quickly and minimize the radiation dose to the public. Measurements are performed in order to minimize the risk to the public by checking the quality of water supplies. For emergency situations, test results are often compared to operational intervention levels. NOTE – Operational intervention levels (OILs) are derived from IAEA Safety Standards[8] or national authorities[9]. A key element of rapid analysis can be the use of routine methods but with a reduced turnaround time. The goal of these rapid measurements is often to check for unusual radioactivity levels in the test sample, to identify the radionuclides present and their activity concentration levels and to establish compliance of the water with intervention levels[10][11][12]. It should be noted that in such circumstances, validation parameters evaluated for routine use (e.g. reproducibility, precision, etc.) may not be applicable to the modified rapid method. However, due to the circumstances arising after an emergency, the modified method may still be fit-for-purpose although uncertainties associated with the test results need to be evaluated and may increase from routine analyses. The first steps of the analytical approach are usually screening methods based on gross alpha and gross beta test methods (adaptation of ISO 10704 and ISO 11704) and gamma spectrometry (adaptation of ISO 20042, ISO 10703 and ISO 19581). Then, if required[13], test method standards for specific radionuclides (see Clause 2) are adapted and applied (for example, 90Sr measurement according to ISO 13160) as proposed in Annex A. This document refers to published ISO documents. When appropriate, this document also refers to national standards or other publicly available documents. Screening techniques that can be carried out directly in the field are not part of this document.


Edition : 20
File Size : 1 file , 2 MB
Number of Pages : 30
Product Code(s) : DS-026, DS-026
Published : 08/31/2020

History


Related products

DANSK DS/EN ISO 16911-1
Published Date: 04/02/2013
Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method
$35.7
DANSK DS/EN 60825-2
Published Date: 11/10/2004
Safety of laser products – Part 2: Safety of optical fibre communication systems (OFCS)
$56.4
DANSK DS/EN 60034-22
Published Date: 12/22/2009
Rotating electrical machines - Part 22: AC generators for reciprocating internal combustion (RIC) engine driven generating sets
$19.2
DANSK DS/EN 61058-2-1
Published Date: 02/08/2011
Switches for appliances – Part 2-1: Particular requirements for cord switches
$19.2

Best-Selling Products

BS IEC 1000-2-6:1995
Published Date: 08/15/1996
Electromagnetic compatibility (EMC). Environment-Assessment of the emission levels in the power supply of industrial plants as regards low-frequency conducted disturbances
$110.49
BS IEC 1000-3-7:1996
Published Date: 02/15/1997
Electromagnetic compatibility (EMC). Limits-Assessment of emission limits for fluctuating loads in MV and HV power systems. Basic EMC publication
$92.964
BS IEC 1000-5-4:1996
Published Date: 12/15/1996
Electromagnetic compatibility (EMC). Installation and mitigation guidelines-Immunity to HEMP. Specifications for protective devices against HEMP radiated disturbance. Basic EMC publication
$79.248
BS IEC 1008-2-2:1990
Published Date: 03/15/1995
Specification for residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCCBs)-Applicability of the general rules to RCCBs functionally dependent on line voltage
$48.006
BS IEC 1009-2-2:1991
Published Date: 03/15/1995
Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs). Applicablity of the general rules to RCBOs-Applicability of the general rules to RCBOs functionally dependent on line voltage
$48.006
BS IEC 50(481):1996
Published Date: 05/15/1997
International electrotechnical vocabulary-Primary cells and batteries
$105.156