DANSK DS/ISO 25539-2 PDF

DANSK DS/ISO 25539-2 PDF

Name:
DANSK DS/ISO 25539-2 PDF

Published Date:
10/05/2020

Status:
[ Active ]

Description:

Cardiovascular implants – Endovascular devices – Part 2: Vascular stents

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$47.4
Need Help?

This document specifies requirements for the evaluation of stent systems (vascular stents and delivery systems) and requirements with respect to nomenclature, design attributes and information supplied by the manufacturer, based upon current medical knowledge. Guidance for the development of in vitro test methods is included in Annex D. This document is supplemental to ISO 14630, which specifies general requirements for the performance of non-active surgical implants. NOTE 1 – Due to the variations in the design of implants covered by this document, and in some cases due to the emergence of novel types of such implants, acceptable standardized in vitro tests and clinical results are not always available. As further scientific and clinical data become available, appropriate revision of this document will be necessary. This document is applicable to vascular stents and vascular scaffolds (e.g. absorbable vascular scaffolds) used to treat vascular stenoses or other vascular abnormalities or pathologies. Some of the requirements are specific to endovascular treatment of arterial stenoses. Although uses of stent systems other than treatment of arterial stenoses (e.g. venous stenting) are within the scope of this document, comprehensive requirements and testing are not described for these uses. Similarly, specific stent configurations (e.g. bifurcation stents) are within the scope, but comprehensive requirements and testing are not described for these devices. Stents used in combination with an endovascular prosthesis to complete the treatment of a lesion, including bridging stents (e.g. stents placed in the renal arteries after deployment of a fenestrated endovascular prosthesis), are within the scope of this document, but test methods are not described for the combination. ISO 25539-1 also provides information relevant to the preclinical in vivo and clinical evaluations of such stents. Vascular stents that have surface modifications, such as drug and/or other coatings, are within the scope of this document. Stents covered with materials that significantly modify the permeability of the uncovered stent (e.g. by covering the stent-free-surface area) are within the scope of ISO 25539-1. The stent design or intended use might dictate the need to address functional requirements identified in both ISO 25539-1 and this document (e.g. stents used in combination with endovascular prostheses, stents used to treat aortic aneurysms). Balloons integral to the stent system are within the scope of this document. This document provides requirements beyond the requirements of ISO 10555-4, which are specific to the use of balloons with vascular stents. This document is not applicable to procedures and devices used prior to the introduction of the vascular stent, such as balloon angioplasty devices. Tacking devices intended to spot treat post-angioplasty dissections, coil supporting devices, and flow diverters are within the scope of this document, but comprehensive requirements and testing are not described for these devices. Although drug-eluting stents are within the scope of this document, this document is not comprehensive with respect to the drug-eluting properties of these devices. NOTE 2 – Vascular device-drug combination products are within the scope of ISO 12417-1. Although absorbable stents and stents with absorbable coatings are within the scope of this document, this document is not comprehensive with respect to the absorbable properties of these devices. NOTE 3 – Absorbable implants are within the scope of ISO/TS 17137. Although coated stents and coated stent systems are within the scope of this document, this document is not comprehensive with respect to coatings. NOTE 4 – Some coating properties are within the scope of ISO 17327-1. This document does not address the requirements for, and the evaluation of, viable tissues and non-viable biologic materials used in the construction of vascular stents.


Edition : 20
File Size : 1 file , 2.3 MB
Number of Pages : 124
Product Code(s) : DS-121, DS-121
Published : 10/05/2020

History


Related products

DANSK DS/EN IEC 60477-2
Published Date: 05/17/2022
Laboratory resistors – Part 2: Laboratory AC resistors
$23.4
DANSK DS/EN 1369
Published Date: 11/29/2012
Founding - Magnetic particle testing
$19.2
DANSK DS/IEC TS 62196-3-1
Published Date: 03/30/2020
Plugs,socket-outlets, vehicle connectors and vehicle inlets – Conductive charging of electric vehicles – Part 3-1: Vehicle connector, vehicle inlet and cable assembly for DC charging intended to be used with a thermal management system
$36.6
DANSK DSF/PREN 4709-003
Published Date:
Aerospace series – Unmanned Aircraft Systems – Part 003: Geo-awareness requirements
$12

Best-Selling Products

ATIS 0100001.2004(S2018)
Published Date: 10/01/2004
User Plane Security Guidelines and Requirements for ETS
$18
ATIS 0100002
Published Date: 07/01/2004
Reliability Aspects of Next Generation Networks
$43.5
ATIS 0100003
Published Date: 11/01/2004
User Plane Priority Levels for IP Networks and Services
$18
ATIS 0100004
Published Date: 01/01/2006
Availability & Restorability Aspects of Emergency Telecommunications Service (ETS)
$33
ATIS 0100005.2006 (S2016)
Published Date: 05/01/2007
Auditory Non-Intrusive Quality Estimation Plus (ANIQUE+): Perceptual Model for Non-Intrusive Estimation of Narrowband Speech Quality
$33
ATIS 0100006
Published Date: 05/01/2006
Service Restoration Priority Levels for IP Networks
$18