DANSK DSF/ETSI EN 302 510 V2.0.1 (2016-09) PDF

DANSK DSF/ETSI EN 302 510 V2.0.1 (2016-09) PDF

Name:
DANSK DSF/ETSI EN 302 510 V2.0.1 (2016-09) PDF

Published Date:

Status:
[ Draft ]

Description:

Short Range Devices (SRD); Ultra Low Power Active Medical Membrane Implants (ULP-AMI-M) and Peripherals (ULP-AMI-M-P) operating in the frequency range 30 MHz to 37,5 MHz; Harmonised Standard covering the essential requirements of article 3.2 of the Directive 2014/53/EU

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$14.7
Need Help?
DRAFT

The present document applies to Ultra Low Power-Active Medical Membrane Implants and Membrane Implant Peripherals as described in Directive 90/385/EEC [i.4], covering all active medical implants, that operate in a Medical Implant Communications System in the frequency band 30 MHz to 37,5 MHz. Table 1: Ultra Low Power Active Medical Membrane Implants and Peripherals operating in the frequency band 30 MHz to 37,5 MHz Ultra Low Power Active Medical Membrane Implants and Peripherals service frequency bands Transmitters – Ultra Low Power Active Medical Membrane Implants and peripherals 30 MHz to 37,5 MHz Receivers – Ultra Low Power Active Medical Membrane Implants and peripherals 30 MHz to 37,5 MHz The present document contains the technical requirements for characteristics of ULP-AMI-M and ULP-AMI-M-P radio equipment which are aligned with annex 12 Sub-band (d) of CEPT/ERC Recommendation 70-03 [i.6]. The frequency usage conditions for the band 30 MHz to 37,5 MHz are EU wide harmonised for the SRD category "active medical implant devices" according to 2013/752/EU [i.10] with the following usage restrictions: • "This set of usage conditions is only available to ultra-low power medical membrane implants for blood pressure measurements within the definition of active implantable medical devices in Directive 90/385/EEC." The present document contains requirements to demonstrate that Ultra Low Power Active Medical Membrane Implants and peripherals used in a medical membrane implant communications system "… shall be so constructed that it both effectively uses and supports the efficient use of radio spectrum in order to avoid harmful interference" (article 3.2 of the Directive 2014/53/EU [i.1]). It does not necessarily include all the characteristics, which may be required by a user, nor does it necessarily represent the optimum performance achievable.


Edition : 16
File Size : 1 file , 730 KB
Number of Pages : 40
Product Code(s) : DSF-036, DSF-036

History


Related products

DANSK DSF/EN 60076-3/FPRA1
Published Date:
Power transformers – Part 3: Insulation levels, dielectric tests and external clearances in air
$4.2
DANSK DS/CEN/TS 17385
Published Date: 11/11/2019
Method for condition assessment of immobile constructed assets
$19.2
DANSK DS/EN 2726
Published Date: 11/26/2018
Aerospace series – Aluminium alloy Al-C42201 – T6 – Sand castings – a ≤ 20 mm
$11.4
DANSK DS/IEC TR 60878
Published Date: 11/07/2022
Graphical symbols for electrical equipment in medical practice
$52.8

Best-Selling Products