DANSK DSF/FPRCEN ISO/TR 22930-2 PDF

DANSK DSF/FPRCEN ISO/TR 22930-2 PDF

Name:
DANSK DSF/FPRCEN ISO/TR 22930-2 PDF

Published Date:

Status:
[ Draft-Obsolete ]

Description:

Evaluating the performance of continuous air monitors – Part 2: Air monitors based on flow-through sampling techniques without accumulation (ISO/TR 22930-2:2020)

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$14.7
Need Help?
DRAFT * W/D S/S BY DS/CEN ISO/TR 22930-2

The use of a continuous air monitor (CAM) is mainly motivated by the need to be alerted quickly and in the most accurate way possible with an acceptable false alarm rate when significant activity concentration value is exceeded, in order to take appropriate measures to reduce exposure of those involved. The performance of this CAM does not only depend on the metrological aspect characterized by the decision threshold, the limit of detection and the measurement uncertainties but also on its dynamic capacity characterized by its response time as well as on the minimum detectable activity concentration corresponding to an acceptable false alarm rate. The ideal performance is to have a minimum detectable activity concentration as low as possible associated with a very short response time, but unfortunately these two criteria are in opposition. It is therefore important that the CAM and the choice of the adjustment parameters and the alarm levels be in line with the radiation protection objectives. This document describes – the dynamic behaviour and the determination of the response time, – the determination of the characteristic limits (decision threshold, detection limit, limits of the coverage interval), and – a possible way to determine the minimum detectable activity concentration and the alarms setup. Finally the annexes of this document show actual examples of CAM data which illustrate how to quantify the CAM performance by determining the response time, the characteristics limits, the minimum detectable activity concentration and the alarms setup.


Edition : 21
File Size : 1 file , 2.5 MB
Number of Pages : 42
Product Code(s) : DSF-036, DSF-036

History

DANSK DSF/FPRCEN ISO/TR 22930-2
Published Date:
Evaluating the performance of continuous air monitors – Part 2: Air monitors based on flow-through sampling techniques without accumulation (ISO/TR 22930-2:2020)
$14.7
DANSK DS/CEN ISO/TR 22930-2
Published Date: 08/30/2021
Evaluating the performance of continuous air monitors – Part 2: Air monitors based on flow-through sampling techniques without accumulation (ISO/TR 22930-2:2020)
$27

Related products

DANSK DS/EN ISO 23322
Published Date: 12/20/2021
Paints and varnishes – Determination of solvents in coating materials containing organic solvents only – Gas-chromatographic method (ISO 23322:2021)
$18
DANSK DS/EN 4529-001
Published Date: 05/30/2006
Aerospace series - Elements of electrical and optical connection - Sealing plugs - Part 001: Technical specification
$13.2
DANSK DS/EN 2243-2
Published Date: 11/23/2005
Aerospace series - Non-metallic materials - Structural adhesives - Test method - Part 2: Peel metal-metal
$13.2
DANSK DS/EN ISO 19448
Published Date: 02/05/2018
Dentistry – Analysis of Fluoride Concentration in Aqueous Solutions by use of Fluoride-Ion Selective Electrode (ISO 19448:2018)
$18

Best-Selling Products

HFES 100
Published Date: 01/01/2007
Human Factors Engineering of Computer Workstations
$28.5
HFES 200
Published Date: 01/01/2008
Human Factors Engineering of Software User Interfaces
$60
HFES 300
Published Date: 01/01/2004
Guidelines for Using Anthropometric Data in Product Design
$25.5
HFES HFES 400
Published Date: 01/01/2021
Human Readiness Level Scale in the System Development Process