Description:

Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices – Part 2-3: Specific assessment for workers with implantable neurostimulators

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$20.7
Need Help?
DRAFT * W/D S/S BY DS/EN 50527-2-3

This document provides the procedure for the specific assessment required in EN 50527 1:2016, Annex A, for workers with implanted neurostimulator systems (NS), specifically of the type used for spinal cord stimulation (SCS). It is recognized that implantable neurostimulators have been developed for a wide variety of clinical applications, however the SCS devices within the scope of this document represent the largest segment of the implantable neurostimulator applications thus far. NOTE 1 – If the worker has other Active Implantable Medical Devices (AIMDs) implanted additionally, they are assessed separately according to EN 50527 1 or other particular standards within the EN 50527 series. The purpose of the specific assessment is to determine the risk for workers with implanted SCS devices arising from exposure to electromagnetic fields (EMF) at the workplace. The assessment includes the likelihood of clinically significant effects and takes both transient and long-term exposure within specific areas of the workplace into account. NOTE 2 – This document does not address risks from contact currents or the effects upon any associated external devices. The techniques described in the different approaches can also be used for the assessment of publicly accessible areas. The frequency range to be observed is from 0 Hz to 3 GHz. Above 3 GHz no interference with the devices within the scope of this document is expected to occur. NOTE 3 – The rationale for limiting the observation range to 3 GHz can be found in ISO 14708 3. NOTE 4 – Further information concerning the functions of neurostimulator systems can be found at https://www.aans.org/Patients/Neurosurgical-Conditions-and-Treatments/Spinal-Cord-Stimulation.


Edition : 21
File Size : 1 file , 4.9 MB
Number of Pages : 106
Product Code(s) : DSF-061, DSF-061

History

DANSK DSF/FPREN 50527-2-3
Published Date:
Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices – Part 2-3: Specific assessment for workers with implantable neurostimulators
$20.7
DANSK DSF/PREN 50527-2-3
Published Date:
Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices – Part 2-3: Specific assessment for workers with implantable neurostimulators
$20.7
DANSK DS/EN 50527-2-3
Published Date: 11/02/2021
Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices – Part 2-3: Specific assessment for workers with implantable neurostimulators
$38.7

Related products

DANSK DS/EN 3475-701
Published Date: 10/30/2017
Aerospace series – Cables, electrical, aircraft use – Test methods – Part 701: Strippability and adherence of insulation to the conductor
$8.4
DANSK DS/EN 4356
Published Date: 01/29/2007
Aerospace series - Six lobe recess - Drivers, short
$11.4
DANSK DS/ISO 9073-3
Published Date: 06/27/2023
Nonwovens – Test methods – Part 3: Determination of tensile strength and elongation at break using the strip method
$19.8
DANSK DS/IEC 62481-6-2
Published Date: 07/31/2017
Digital living network alliance (DLNA) home networked device interoperability guidelines – Part 6-2: Remote user interface – RVU
$16.8

Best-Selling Products

EUROCAE ED-100A
Published Date: 04/01/2005
INTEROPERABILITY REQUIREMENTS FOR ATS APPLICATIONS USING ARINC 622 DATA COMMUNICATIONS (FANS 1/A INTEROP STANDARD)
$56.7
EUROCAE ED-101
Published Date: 08/01/2000
MINIMUM OPERATIONAL PERFORMANCE SPECIFICATION FOR MODE S SPECIFIC SERVICE APPLICATIONS
EUROCAE ED-102A
Published Date: 12/01/2009
Minimum Operational Performance Standards for 1090 MHz Extended Squitter Automatic Dependent Surveillance – Broadcast (ADS-B) and Traffic Information Services – Broadcast (TIS-B)
EUROCAE ED-102A
Published Date: 01/01/2012
Minimum Operational Performance Standards for 1090 MHz Extended Squitter Automatic Dependent Surveillance – Broadcast (ADS-B) and Traffic Information Services – Broadcast (TIS-B)
EUROCAE ED-102B CHG 1
Published Date: 01/01/2022
MINIMUM OPERATIONAL PERFORMANCE STANDARDS (MOPS) FOR 1090 MHZ EXTENDED SQUITTER AUTOMATIC DEPENDENT SURVEILLANCE - BROADCAST (ADS-B) AND TRAFFIC INFORMATION SERVICES-BROADCAST (TIS-B) - CHANGE 1
$48.6
EUROCAE ED-102B
Published Date: 12/01/2020
MINIMUM OPERATIONAL PERFORMANCE STANDARDS (MOPS) FOR 1090 MHZ EXTENDED SQUITTER AUTOMATIC DEPENDENT SURVEILLANCE ‐ BROADCAST (ADS‐B) AND TRAFFIC INFORMATION SERVICES‐BROADCAST (TIS‐B)
$311.1