DANSK DSF/FPREN 62271-110 PDF

DANSK DSF/FPREN 62271-110 PDF

Name:
DANSK DSF/FPREN 62271-110 PDF

Published Date:

Status:
[ Draft ]

Description:

High-voltage switchgear and controlgear – Part 110: Inductive load switching

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
dansk-dsf-fpren-62271-110_2698618

Choose Document Language:
12.00 €
Need Help?
DRAFT

This part of IEC 62271 is applicable to a.c. switching devices designed for indoor or outdoor installation, for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 000 V and applied for inductive current switching. The standard is applicable to switching devices (including circuit-breakers in accordance with IEC 62271-100) that are used to switch high-voltage motor currents and shunt reactor currents and also to high-voltage contactors used to switch high-voltage motor currents as covered by IEC 62271-106. For circuit-breakers applied to switch shunt reactor currents at rated voltages according to IEC 62271-1:2016 the requirements related to combined voltage tests across the isolating distance (Tables 3 and 4), are not applicable. Switching unloaded transformers, i.e. breaking transformer magnetizing current, is not considered in this standard. The reasons for this are as follows: a) due to the non-linearity of the transformer core, it is not possible to correctly model the switching of transformer magnetizing current using linear components in a test laboratory. Tests conducted using an available transformer, such as a test transformer, will only be valid for the transformer tested and cannot be representative for other transformers; b) as detailed in IEC/TR 62271-306, the characteristics of this duty are usually less severe than any other inductive current switching duty. It should be noted that such a duty may produce severe overvoltages within the transformer winding(s) depending on the re-ignition behaviour of the switching device and transformer winding resonance frequencies. NOTE 1 – The switching of tertiary reactors from the high-voltage side of the transformer is not covered by this standard. NOTE 2 – The switching of shunt reactors earthed through neutral reactors is not covered by this standard. However, the application of test results according to this standard, on the switching of neutral reactor earthed reactors (4-leg reactor scheme), is discussed in IEC/TR 62271-306.


Edition : 17
File Size : 1 file , 1.6 MB
Number of Pages : 31
Product Code(s) : DSF-021, DSF-021

History


Related products

DANSK DS/ISO 20906
Published Date: 01/14/2010
Acoustics - Unattended monitoring of aircraft sound in the vicinity of airports
42.60 €
DANSK DS/EN ISO 12932
Published Date: 07/22/2013
Welding - Laser-arc hybrid welding of steels, nickel and nickel alloys - Quality levels for imperfections
23.40 €
DANSK DS/EN 4179
Published Date: 01/03/2022
Aerospace series – Qualification and approval of personnel for non-destructive testing
23.40 €
DANSK DS/EN 16603-10-12
Published Date: 07/23/2014
Space engineering - Method for the calculation of radiation received and its effects, and a policy for design margins
38.70 €

Best-Selling Products

Advanced Compiler Design & Implementation
Published Date: 01/01/1997
27.00 €
Computer Networks : A Systems Approach
Published Date: 10/01/1999
24.00 €
Exploring 3D Graphics
Published Date: 05/01/1999
Radiosity & Global Illumination
Published Date: 01/01/1994
16.20 €