DANSK DSF/FPREN IEC 60947-9-2 PDF

DANSK DSF/FPREN IEC 60947-9-2 PDF

Name:
DANSK DSF/FPREN IEC 60947-9-2 PDF

Published Date:

Status:
[ Draft ]

Description:

Low-voltage switchgear and controlgear – Part 9-2: Active arc-fault mitigation systems – Optical-based internal arc-detection and mitigation devices

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$20.7
Need Help?
DRAFT

This document covers internal arc-fault control devices, hereinafter referred to as IACD, which are intended to: - detect internal arc-faults in low-voltage switchgear and controlgear assemblies, by processing (at a minimum) the optical effect of an internal arc-fault, and - operate mitigation device (either external or combined) in order to minimize the effects of the internal arc-fault (see Figure 1). For the purpose of this document the terms "light" or "optical" covers more than visible spectra. They may cover also, for example, infrared or ultraviolet electromagnetic radiations (see Annex D). For combined-type IACD, this document is considered in addition to the relevant product standard for internal arc-fault mitigation devices (IARD per IEC TS 63107:2020). Compliance to the relevant product standard is mandatory and cannot be claimed by testing to this document alone. NOTE 1 – Low-voltage switchgear and controlgear assemblies are usually described by IEC 61439 series. [Figure 1] Therefore, this document covers the following: - internal arc-fault control device (stand-alone, multifunction or combined); - one or more associated sensor(s) used to detect optical effect of the internal arc-fault; - sensor(s), sensing another physical effect, to confirm the fault; - associated or combined mitigation device. An IACD is not intended to trigger under normal operation of low-voltage switchgear and controlgear (i.e. absence of internal arc-fault), including normal arcing associated with operation of disconnecting and switching devices. This document only covers the following methods: - optical detection of the light caused by an internal arc-fault; - optional confirmation of internal arc-fault by line current measurement. Many different conductive materials could be used in LV assemblies (e.g. steel, copper, aluminium). Nevertheless, tests specified in this document are deemed to represent the most critical and challenging conditions for ar ...


Edition : 21
File Size : 1 file , 3.7 MB
Number of Pages : 89
Product Code(s) : DSF-061, DSF-061

History

DANSK DSF/PREN IEC 60947-9-2
Published Date:
Low-voltage switchgear and controlgear – Active arc-fault mitigation systems – Part 9-2: Optical-based internal arc-detection and mitigation devices
$20.7
DANSK DSF/FPREN IEC 60947-9-2
Published Date:
Low-voltage switchgear and controlgear – Part 9-2: Active arc-fault mitigation systems – Optical-based internal arc-detection and mitigation devices
$20.7

Related products

DANSK DS/ISO/IEC 30108-1
Published Date: 11/13/2015
Information technology - Biometric Identity Assurance Services - Part 1: BIAS services
$39.6
DANSK DS/EN 12420
Published Date: 07/18/2014
Copper and copper alloys – Forgings
$33
DANSK DS/ISO 18334
Published Date: 08/06/2010
Pallets for materials handling - Quality of assembly of new wooden pallets
$16.8
DANSK DS/EN 10028-6
Published Date: 08/01/2017
Flat products made of steels for pressure purposes – Part 6: Weldable fine grain steels, quenched and tempered
$13.2

Best-Selling Products