DANSK DSF/FPREN IEC 61558-2-15 PDF

DANSK DSF/FPREN IEC 61558-2-15 PDF

Name:
DANSK DSF/FPREN IEC 61558-2-15 PDF

Published Date:

Status:
[ Draft ]

Description:

Safety of transformers, reactors, power supply units and combinations thereof – Part 2-15: Particular requirements and tests for isolating transformers for medical IT systems for the supply of medical locations

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$12
Need Help?
DRAFT

This part of IEC 61558 deals with safety of isolating transformers for medical IT systems for the supply of medical locations. NOTE 1 – Safety includes electrical, thermal and mechanical aspects. Unless otherwise specified, from here onward, the term transformer covers isolating transformers for medical IT systems for the supply of medical locations. This document is applicable to isolating transformers, single-phase or three-phase, air-cooled (natural or forced) dry-type transformers for the supply of medical IT system for group 2 medical locations, designed to be permanently connected to the fixed wiring and intended to form the medical IT system on the secondary side. The windings can be encapsulated or non encapsulated. NOTE 2 – IT systems are defined in IEC 60364-1. The installation rules for medical IT system for group 2 medical locations are covered by IEC 60364-7-710. Transformers covered by this document are intended for medical IT systems for the supply of medical locations. All other transformers or equipments connected downstream from the transformer are not covered by this document. The rated supply voltage does not exceed 1 000 V AC. The rated supply frequency and internal operational frequency do not exceed 500 Hz. The rated output does not be less than 0,5 kVA and does not exceed 10 kVA for single-phase and three-phase transformers for medical IT system for group 2 medical locations. This document may be applicable to isolating transformers intended to supply other medical installations that are not group 2 medical locations without limitation of the rated output subject to an agreement between the purchaser and the manufacturer. NOTE 3 – Transformers intended to supply distribution networks other than medical IT systems are not included in the scope. The no-load output voltage and the rated output voltage does not exceed 250 V AC for single-phase or three-phase transformer (phase-to-phase voltage). This document does not cover power suppl ...


Edition : 22
File Size : 1 file , 1 MB
Number of Pages : 23
Product Code(s) : DSF-021, DSF-021

History

DANSK DSF/FPREN IEC 61558-2-15
Published Date:
Safety of transformers, reactors, power supply units and combinations thereof – Part 2-15: Particular requirements and tests for isolating transformers for medical IT systems for the supply of medical locations
$12
DANSK DSF/PREN IEC 61558-2-15
Published Date:
Safety of transformers, reactors, power supply units and combinations thereof – Part 2-15: Particular requirements and tests for isolating transformers for medical IT systems for the supply of medical locations
$12

Related products

DANSK DS/ISO/IEC 2382-37
Published Date: 04/04/2022
Information technology – Vocabulary – Part 37: Biometrics
$30
DANSK DS/EN ISO 2818
Published Date: 01/14/2019
Plastics – Preparation of test specimens by machining (ISO 2818:2018)
$19.2
DANSK DS/ISO 15639-1
Published Date: 08/04/2015
Radio frequency identification of animals - Standardization of injection sites for different animal species - Part 1: Companion animals (cats and dogs)
$16.8
DANSK DS/EN 54-12
Published Date: 04/22/2015
Fire detection and fire alarm systems – Part 12: Smoke detectors – Line detectors using an optical beam
$33

Best-Selling Products

ASHRAE/ICC/USGBC/IES 189.1-2017 Addendum a
Published Date: 2019
Addendum a to Standard 189.1-2017 for the Design of High-Performance Green Buildings Except Low-Rise Residential Buildings (ANSI Approved; ICC, USGBC and IES Co-sponsored)
Free Download
ASHRAE/ICC/USGBC/IES 189.1-2017 Addendum aa
Published Date: 2020
Addendum aa to Standard 189.1-2017 for the Design of High-Performance Green Buildings Except Low-Rise Residential Buildings (ANSI Approved; ICC, USGBC and IES Co-sponsored)
Free Download
ASHRAE/ICC/USGBC/IES 189.1-2017 Addendum ab
Published Date: 2020
Addendum ab to Standard 189.1-2017 for the Design of High-Performance Green Buildings Except Low-Rise Residential Buildings (ANSI Approved; ICC, USGBC and IES Co-sponsored)
Free Download
ASHRAE/ICC/USGBC/IES 189.1-2017 Addendum ac
Published Date: 2020
Addendum ac to Standard 189.1-2017 for the Design of High-Performance Green Buildings Except Low-Rise Residential Buildings (ANSI Approved; ICC, USGBC and IES Co-sponsored)
Free Download
ASHRAE/ICC/USGBC/IES 189.1-2017 Addendum ad
Published Date: 2019
Addendum ad to Standard 189.1-2017 for the Design of High-Performance Green Buildings Except Low-Rise Residential Buildings (ANSI Approved; ICC, USGBC and IES Co-sponsored)
Free Download
ASHRAE/ICC/USGBC/IES 189.1-2017 Addendum ae
Published Date: 2020
Addendum ae to Standard 189.1-2017 for the Design of High-Performance Green Buildings Except Low-Rise Residential Buildings (ANSI Approved; ICC, USGBC and IES Co-sponsored)
Free Download