Name:
DANSK DSF/FPREN ISO 15512 PDF
Published Date:
Status:
[ Draft ]
Publisher:
Dansk Standard
1.1 This document specifies methods for the determination of the water content of plastics in the form of powder, granules, and finished articles. These methods do not test for water absorption (kinetics and equilibrium) of plastics as measured by ISO 62. Method A is suitable for the determination of water content as low as 0,1 % with an accuracy of 0,1 %. Method B and Method C are suitable for the determination of water content as low as 0,01 % with an accuracy of 0,01 %. Method D is suitable for the determination of water content as low as 0,01% with an accuracy of 0,01%. Method E is suitable for the determination of water content as low as 0,001% with an accuracy of 0,001%. The stated accuracies are detection limits which depend also on the maximal possible sample weight. Percentage means percentage of water content. Method D is suitable for polyamide (PA), polycarbonate (PC), polypropylene (PP), polyethylene (PE), epoxy resin, polyethylene terephthalate (PET), polyester, polytetrafluoroethylene (PTFE), polyvinyl chloride (PVC), polyactide (PLA), polyamidimid (PAI), it is especially not recommended for samples which may release NH3. Method E is generally suitable for every type of plastic and moisture level. Water content is an important parameter for processing materials and has to remain below the level specified in the appropriate material standard.
| Edition : | 19 |
| File Size : | 1 file , 1.8 MB |
| Number of Pages : | 44 |
| Product Code(s) : | DSF-036, DSF-036 |