DANSK DSF/ISO/DIS 14146 PDF

DANSK DSF/ISO/DIS 14146 PDF

Name:
DANSK DSF/ISO/DIS 14146 PDF

Published Date:

Status:
[ Draft-Obsolete ]

Description:

Radiological protection – Criteria and performance limits for the periodic evaluation of dosimetry services

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$13.5
Need Help?
DRAFT

The quality of a supplier of a dosimetry service depends on both the characteristics of the approved (type‑tested) dosimetry system[1] and the training and experience of the staff, together with the calibration procedures and quality assurance programmes. This document specifies the criteria and the test procedures to be used for the periodic verification of the performance of dosimetry services supplying personal and/or area dosemeters. An area dosemeter can be a workplace dosemeter or an environmental dosemeter. The performance evaluation can be carried out as a part of the approval procedure for a dosimetry system or as an independent check to verify that a dosimetry service fulfils specified national or international type test performance requirements under representative exposure conditions that are expected or mimic workplace fields from the radiological activities being monitored. This document applies to personal and area dosemeters for the assessment of external photon radiation with a (fluence weighted) mean energy between 8 keV and 10 MeV, beta radiation with a (fluence weighted) mean energy between 60 keV and 1,2 MeV, and neutron radiation with a (fluence weighted) mean energy between 25,3 meV (i.e. thermal neutrons with a Maxwellian energy distribution with kT = 25,3 meV) and 200 MeV. It covers all types of personal and area dosemeters needing laboratory processing (e.g. thermoluminescent, optically stimulated luminescence, radiophotoluminescent, track detectors or photographic-film dosemeters) and involving continuous measurements or measurements repeated regularly at fixed time intervals (e.g. several weeks, one month). Active dosemeters (for dose measurement) may also be treated according to this document. Then, they should be treated as if they were passive (i.e. the dosimetry service reads their indicated values and reports them to the evaluation organization). [1] If this document is applied to a dosimetry system for which no approval (pattern or type test) has been provided, then in the following text approval or type test should be read as the technical data sheet provided by the manufacturer or as the data sheet required by the regulatory authority.


Edition : 23#
File Size : 1 file , 1.8 MB
Number of Pages : 24
Product Code(s) : DSF-021, DSF-021

History

DANSK DSF/ISO/DIS 14146
Published Date:
Radiological protection – Criteria and performance limits for the periodic evaluation of dosimetry services
$13.5
DANSK DS/ISO 14146
Published Date: 07/28/2020
Radiological protection – Criteria and performance limits for the periodic evaluation of dosimetry services
$16.8

Related products

DANSK DS/EN 12999
Published Date: 10/19/2020
Cranes – Loader cranes
$38.7
DANSK DSF/ISO/DIS 24014-1
Published Date:
Public transport – Interoperable fare management system – Part 1: Architecture
$23.1
DANSK DS/EN ISO 9455-5
Published Date: 10/19/2020
Soft soldering fluxes – Test methods – Part 5: Copper mirror test (ISO 9455-5:2020)
$13.2
DANSK DS/ISO 22248
Published Date: 01/02/2024
Lasers and laser-related equipment – Test methods for laser-induced damage threshold – Classification of medical beam delivery systems
$21.3

Best-Selling Products