DANSK DSF/PREN 63052 PDF

DANSK DSF/PREN 63052 PDF

Name:
DANSK DSF/PREN 63052 PDF

Published Date:

Status:
[ Draft ]

Description:

Power frequency overvoltage protective devices for household and similar applications (POP)

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$20.7
Need Help?
DRAFT

This document applies to devices for power frequency overvoltage protection (hereafter referred to as “POP”) for household and similar uses, with a rated frequency of 50 Hz, 60 Hz or 50/60 Hz, with rated voltage not exceeding 230 V a.c. (between phase and neutral), and with rated current not exceeding 63 A, either consisting of a functional unit in combination with a main protective device (MPD), or as one single device having opening means able to open the protected circuit in specified conditions. The main protective device is a circuit-breaker, an RCCB or an RCBO. NOTE 1 – A POP, as one single device, is not a protective device to be used for automatic disconnection of the supply in the meaning of IEC 60364-4-41. They are intended for use in an environment with pollution degree 2 and overvoltage category III. Devices for POPs are suitable for isolation. They can be designed as a POP unit assembled to or integrated in a main protective device by the manufacturer or as an assembly of a main protective device mechanically or electrically coupled on site with the POP unit, or as one single POP device having opening means able to open the protected circuit in specified conditions. These devices are intended to mitigate the effects of power frequency overvoltages between phase and neutral conductor (e.g. caused by loss of neutral conductor in the three-phase supply upstream the POP) for downstream equipment by opening the protected circuit when an overvoltage between phase and neutral is detected. NOTE 2 – To mitigate means in this context that the POP will provide protection in most cases of power frequency overvoltages. POPs intended for monitoring one line to neutral conductor voltage can be used between two phase’s conductors in a phase to phase electrical supply system not exceeding 230 V, if both conductors are switched and declared so by the manufacturer. POP according to this document are suitable for use in IT system, provided all conductors are switched. This document does not apply for protection against common mode overvoltages. This document does not apply to surge protective devices.


Edition : 18
File Size : 1 file , 2.5 MB
Number of Pages : 112
Product Code(s) : DSF-061, DSF-061

History


Related products

DANSK DS/ISO 24355
Published Date: 05/16/2023
Flight control system for civil small and light multicopter unmanned aircraft system (UAS) – General requirements
$16.8
DANSK DS/IEC TS 60601-4-2
Published Date: 04/02/2024
Medical electrical equipment – Part 4-2: Guidance and interpretation – Electromagnetic immunity: performance of medical electrical equipment and medical electrical systems
$36.6
DANSK DS/EN IEC 61969-1
Published Date: 03/28/2023
Mechanical structures for electrical and electronic equipment – Outdoor enclosures – Part 1: Design guidelines
$18

Best-Selling Products

AISI CF03-1
Published Date:
STEEL STUD BRICK VENEER DESIGN GUIDE
AISI CF06-1P
Published Date: 01/01/2004
DIRECT STRENGTH METHOD DESIGN GUIDE (DSM)
AISI CF87-1
Published Date: 01/01/1987
DEVELOPMENT OF A UNIFIED APPROACH TO THE DESIGN OF COLD-FORM
AISI CF92-2
Published Date: 01/01/1992
SHEAR RESISTANCE OF WALLS WITH STEEL STUDS
AISI CF93-1
Published Date: 01/01/1993
PRELIMINARY DESIGN GUIDE FOR COLD-FORMED STEEL C- AND Z-MEMB
AISI D100-08
Published Date: 01/01/2008
2008 Edition of the Cold-Formed Steel Design Manual