DANSK DSF/PREN IEC 61558-2-2 PDF

DANSK DSF/PREN IEC 61558-2-2 PDF

Name:
DANSK DSF/PREN IEC 61558-2-2 PDF

Published Date:

Status:
[ Draft ]

Description:

Safety of transformers, reactors, power supply units and combinations thereof – Part 2-2: Particular requirements and tests for control transformers and power supply units incorporating control transformers

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$8.7
Need Help?
DRAFT

This part of IEC 61558 deals with the safety of control transformers and power supply units incorporating control transformers. Transformers incorporating electronic circuits are also covered by this document. NOTE 1 – Safety includes electrical, thermal and mechanical aspects. Unless otherwise specified, from here onward, the term transformer covers control transformers and power supply units incorporating control transformers. For power supply units (linear) this document is applicable. For switch mode power supply units IEC 61558-2-16 is applicable together with this document. Where two requirements are in conflict, the most severe take precedence. This document does not apply to transformers covered by IEC 60076-11. This document is applicable to stationary or portable, single-phase or polyphase, air-cooled (natural or forced) independent or associated dry- type transformers. The windings can be encapsulated or non-encapsulated. The rated supply voltage does not exceed 1 000 V AC and the rated supply frequency and the internal operating frequencies do not exceed 500 Hz. The rated thermal output does not exceed: - 25 kVA for single-phase transformers, - 40 kVA for polyphase transformers; This document is applicable to transformers without limitation of the rated thermal output, subject to an agreement between the purchaser and the manufacturer. NOTE 2 – Transformers intended to supply distribution networks are not included in the scope. The no-load output voltage or the rated output voltage does not exceed 1 000 V AC or 1 415 V ripple-free DC. For independent transformers the no-load output voltage and / or the rated output voltage is not less than 50 V AC or 120 V ripple-free DC. This document is not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers. NOTE 3 – Transformers covered by this document are only used in applications where double or reinforced insulat ...


Edition : 21
File Size : 1 file , 1.1 MB
Number of Pages : 18
Product Code(s) : DSF-009, DSF-009

History


Related products

DANSK DS/EN 60674-3-7
Published Date: 10/01/1998
Specification for plastic films for electrical purposes – Part 3: Specifications for individual materials – Sheet 7: Requirements for fluoroethylene-propylene (FEP) films used for electrical insulation
$8.4
DANSK DS/EN 60630
Published Date: 03/02/1999
Maximum lamp outlines for incandescent lamps
$8.4
DANSK DSF/FPREN ISO 20846
Published Date:
Petroleum products – Determination of sulfur content of automotive fuels – Ultraviolet fluorescence method (ISO/FDIS 20846:2019)
$8.7
DANSK DS/EN 14367
Published Date: 09/29/2005
Non controllable backflow preventer with different pressure zones - Familiy C, type A
$22.5

Best-Selling Products